ESIE16-03B
|
Part 5. Appendix
5.1. Field setting
SA R32 Sky-Air RZAG-L
22/08/16
|
Version 1.1
Page 99
5.1. Field setting
5.1.1. Indoor unit
5.1.1.1. Retrieve field settings BRC1E
1. Press and hold Cancel button for 4 seconds or more. Field setting menu is displayed.
2. Select
Field setting list
in the field setting menu, and press Menu/Enter button.
Field setting list screen is displayed.
3. Highlight the mode, and select desired “Mode No.” by using
▲▼
(Up/Down) button.
4. In the case of setting per indoor unit during group control (When Mode No. such as
20
,
21
,
22
,
23
,
25
are selected), highlight the unit No. and select “Indoor unit No.” to be set by using
▲▼
(Up/Down) button. (In the case of group total setting, this operation is not needed.)
In the case of individual setting per indoor unit, current settings are displayed. And, Second Code No. “-” means no function.
5. Highlight Second Code No. of the First Code No. to be changed, and select desired “Second Code No.” by using
▲▼
(Up/Down) button. Multiple identical mode number settings are
available.
In the case of group total setting, all of Second Code No. which may be set are displayed as “*”.
“*” is changed to Second Code No. to be set. And, Second Code No. “-” means no function.
(1)
(2)
(3)
(4)
(5)
(3)
(5)
(6)
(7)
<Basic screen>
<Field setting menu screen>
<Field setting screen>
In the case of individual
setting per indoor unit
Second Code No.
Press Menu/Enter button.
In the case of group total
setting
<Setting confirmation screen>
Press Menu/Enter button.
First Code (SW) No.
<Setting confirmation>
Press Menu/Enter button.