5.3. Wiring diagram
5.3.1. Indoor unit
Figure 5-1: Wiring diagram - indoor unit
Notes
1. In case using central remote controller, connect it to the unit in accordance with the attached installation manual.
2. In case of main/sub changeover. See the installation manual attached to remote controller.
3. Shows only in case of protected pipes. Use H07RN in case of no protection.
4. When connecting the input wires from outside, forced off or on/off control operation can be selected by the remote controller. See installation manual for more details.
5. Connect power of adapter for wiring to terminal block (X2M) of indoor unit directly.
6. X35A, X39A, X70A are connected when the optional accessories are being used. In case an auto cleaning panel is used, see the wiring diagram.
Legend
V1R (A1P)
Diode module
A1P
Main PCB
X1A (A7P)
Connector (power supply for option PCB)
A2P
Adapter PCB
X2A (A7P)
PCB connector (sensor kit)
A3P, A4P
* Sensor kit PCB
X24A (A1P)
PCB connector (wireless remote controller)
A5P, A6P
Receiver/display PCB
X33A (A1P)
PCB connector (adapter for wiring)
A7P
* Adapter for wiring
X35A (A1P)
PCB connector (auto clean panel)
BS01 (A6P)
Push button (ON/Off)
X39A (A1P)
PCB connector (auto clean panel)
C105 (A1P)
Capacitor
X70A (A1P)
PCB connector (auto clean panel)
DS1 (A1P)
DIP switch
X*A
PCB connector
F1U (A7P)
Fuse B, 5 A 250 V
X*M
Terminal strip
F2U (A7P)
Fuse B, 5 A 250 V
X*Y
Connector
HAP (A1P)
Running LED (service monitor-green)
Z*C
Noise filter (ferrite core)
H1P (A6P)
LED (On-red)
Z*F
Noise filter
H2P (A6P)
LED (timer-green)
* Optional
H3P (A6P)
LED (filtersign-red)
# Field supply
H4P (A6P)
LED (defrost-orange)
H5P (A6P)
LED (element cleaning-red)
Symbols
H6P (A6P)
LED (ventilation cleaning-green)
X1M
Main terminal
KCR (A7P)
Magnetic relay
Earth wiring
KFR (A7P)
Magnetic relay
Wire number 15
KHuR (A7P)
Magnetic relay (Hu)
Field wire
K2R
Magnetic relay
Field cable
M1F
Fan motor (indoor)
Connection ** continues on page 12 column 2
M1P
Motor (drain pump)
Several wiring possibilities
M*S
Motor (swing flap)
Option
PS (A1P)
Power supply
Not mounted in switch box
R1T
Thermistor (air)
Wiring depending on model
R2T
Thermistor (liquid piping)
PCB
R3T
Thermistor (coil)
RC (A1P)
Signal receiver circuit
Colours
SS1 (A5P)
Selector switch (emergency)
BLK:
Black
SS2 (A5P)
Selector switch (wireless address set)
WHT:
White
S1L
Float switch
RED:
Red
TC (A1P)
Signal transmission circuit
A1P
A3P
A4P
A7P
A2P
X2A
F1U
X1A
KhUr
KFR
KCR
X2M 1 2 3
2
1
3 4 5 6
X33A
X35A
X20A
1 2 3 4 5 6
1
3
5
2
4
BLK
WHT
RED
1 2 3
1 2 3 4
1 2 3
2
1
2
1
X17A
X16A
X83A
X15A
X18A
X39A
1
2
PS
H05VV-U4G2,5
Z2C R3T
S1L
R2T
R1T
t°
t°
t°
1 2 3 4
HAP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1
2
1 2 3
5 6
4
7 8 9 10
1 2 3
5 6
4
7 8
X81A
X30A
ON
OFF
1 2 3
1
2
3
4
5
3
2
1
4
5
1
2
3
4
5
6
7
8
9
3
2
1
4
5
6
7
8
9
H1P
H2P
H3P
H4P
H5P
H6P
X70A
5
8
1 2
2
1
3
6 7
4
M
M
M
M
X36A
X25A
OFF ON
OFF ON
1
1
M4S
M3S
M2S
M1S
N=1
CN1
F2U
1
2
RC
TC
A5P
A6P
M1F
M1P
1 2 3 4
1 2 3 4 5 6
t°
R1T
Y2
YC
X1
X2
X3
X4
NORM.
EMG
BS1
N
P
4D099158-1
1 2
X2A
X1A
X1A
X24A
SS1
SS2
T2 T1 F2 F1 P N
DS1
X27A
K2R
X1M
C105
V1R
MS
Z1F
NE
PE
Z1C
N=1
X1Y
1 2 3 4 5
MS
Terminal for operation display
Compressor
operation
Sensor kit
User interface
Central remote controller (see note 1)
Input from outside (see note 4)
Fan operation
Adapter for wiring (see note 5)
Receiver / display unit
(see note 6)
(see
note 6)
(see note 6)
(see note 3)
Outdoor
(see note 2)