5.6.1.1. “E9-00” - Electronic expansion valve abnormality
Trigger conditions
•
A = 4 K
•
B = 10 K
5.6.1.2. “F3-00” - Discharge pipe temperature abnormality
5.6.2. Component checklist
5.6.2.1. How to activate inverter test
Not available yet.
5.6.2.2. Component checklist
Compressor
A (°C)
B (°C)
C (°C)
2YC71
120
110
/
2YC100
120
110
/
Component
Component name
Connector on 71-class
Connector on 100/140-class
PCB
Specific
Outdoor unit
M1C
Motor (compressor)
X502A
X502A
A1P
M1F
Motor (upper fan)
X106A
X106A
A1P
M2F
Motor (lower fan)
X107A
A1P
S1PH-A
Automatic high pressure switch
X32A
X32A
A1P
S1PH-M
Manual high pressure switch
X32A
X32A
A1P
S1PL
Low pressure switch
X31A
X31A
A1P
Y1E
Electronic expansion valve
X21A
X21A
A1P
Y3E
Electronic expansion valve
X22A
X22A
A1P
Y1S
Solenoid valve (4-way valve)
X25A
X25A
A1P
Y2S
Solenoid valve
X26A
X26A
A1P
R1T
Thermistor (air)
X11A
X11A
A1P
Type 1
R2T
Thermistor (discharge)
X12A
X12A
A1P
Type 2
R3T
Thermistor (suction)
X12A
X12A
A1P
Type 1
R4T
Thermistor (heat exchanger inlet)
X12A
X12A
A1P
Type 1
R5T
Thermistor (heat exchanger middle)
X12A
X12A
A1P
Type 1
R6T
Thermistor (liquid)
X13A
X13A
A1P
Type 1