![background image](http://html2.mh-extra.com/html/daikin/ftyn25gxv1b/ftyn25gxv1b_service-manual_4701921032.webp)
SiBE01-829
Functions
Functions and Control
21
1.7
POWERFUL Operation
Outline
In order to exploit the cooling and heating capacity to full extent, operate the air conditioner by
increasing the indoor fan rotating speed.
Details of the
Control
When POWERFUL button is pushed, the fan speed and the target temperature will be
converted to the following states for 20 minutes.
Ex.) : POWERFUL operation in cooling mode.
Operation mode
Fan speed
Target temperature
Cooling
HH tap
Set temp. –2°C
Heating
HH tap
Set temp. +2°C
(R8496)
Target temp.
Fan
Set temp.
Set temp. –2˚C
POWERFUL ON
POWERFUL OFF
HH tap
Set tap
It counts 20 min. also in the remote controller.
Ending condition: "or" in 1 to 3
1. After the lapse of 20 minutes.
2. POWERFUL operation is OFF.
3. Operation halts.
20min.