SiBE01-829
Others
Others
107
1.3
Jumper Settings
1.3.1 When Two Units are Installed in One Room
How to set the different addresses.
When two indoor units are installed in one room, the two wireless remote controllers can be
set for different addresses.
PCB in the indoor unit
Remove the front panel.
Remove the electrical parts box (1-screw).
Slide the metallic cover to remove it. (4-claws on the electrical parts box.)
Cut the jumper
JA
on PCB.
Wireless remote controller
Cut the jumper
J4
.
1.3.2
Jumper Setting
(R4758)
Address
J4
CUT
EXIST
1
2
Metallic
cover
PCB
Electric
parts box
Claws (4 points)
Wireless
remote
controller
J4
CUT
2
ADDRESS: JA
EXIST
1
JA
JC
C1
C31
J30
JP11
ADDRESS
Jumper
(On indoor control PCB)
Function
When connected
(factory set)
When cut
JC
Power failure
recovery function
Auto re-start
Unit does not resume operation
after recovering from a power
failure. Timer ON-OFF settings
are cleared.
Summary of Contents for FTYN25GXV1B
Page 1: ...SiBE01 829 Applied Models Non Inverter Pair Heat Pump SPLIT Pair Wall Mounted Type G Series...
Page 11: ...Introduction SiBE01 829 x...
Page 12: ...SiBE01 829 List of Function 1 Part 1 List of Function 1 Functions 2...
Page 15: ...Functions SiBE01 829 4 List of Function...
Page 16: ...SiBE01 829 Specifications 5 Part 2 Specifications 1 Specifications 6...
Page 19: ...Specifications SiBE01 829 8 Specifications...
Page 81: ...Check SiBE01 829 70 Service Diagnosis...
Page 86: ...Others SiBE01 829 108 Others...
Page 92: ...Wiring Diagrams SiBE01 829 114 Appendix...