![background image](http://html1.mh-extra.com/html/daikin/ftxn09kevju/ftxn09kevju_service-manual_3342033166.webp)
Indoor Unit: 15/18/24 Class
SiUS041111
158
Removal Procedure
6
Remove the screw and
remove the terminal
board.
You can remove the electrical
box without detaching the
terminal board.
Screw: M4 × 30
7
Disconnect the
connector for the fan
motor [S1].
8
Disconnect the
connector for the swing
motor [S6].
[S6]: for horizontal blades
9
Remove the screw of
the electrical box.
Step
Procedure
Points
Terminal board
(R2773)
[S1]
(R2774)
(R14254)
[S6]
Electrical box
(R3205)