![background image](http://html1.mh-extra.com/html/daikin/ftxn09kevju/ftxn09kevju_service-manual_3342033152.webp)
Indoor Unit: 09/12 Class
SiUS041111
144
Removal Procedure
5
Disconnect the flare nut
for liquid piping with 2
wrenches.
2. Remove the indoor heat
exchanger.
1
Remove the indoor unit
from the installation
plate.
2
Unfasten the hook of
the piping fixture on the
back of the indoor unit.
Step
Procedure
Points
(R8018)
Gas piping
Liquid piping
(R8019)
Auxiliary piping
Piping fixture
(R8038)
(R8039)