![background image](http://html1.mh-extra.com/html/daikin/ftxn09kevju/ftxn09kevju_service-manual_3342033163.webp)
SiUS041111
Indoor Unit: 15/18/24 Class
Removal Procedure
155
2.3
Removal of Horizontal Blades / Vertical Blades
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the horizontal
blades.
1
Open the horizontal
blades.
2
Bend the horizontal
blade slightly and
release the center
shaft. (2 locations)
Remove both the horizontal
blades (upper and lower) in the
same way.
3
Release the left shaft.
4
Slide the horizontal
blade to the left and
release the right shaft.
Installation procedure
1. Since the key pattern hook is
provided, rotate the blade and fit
it to the right shaft first.
2. Fit the blade to the center and
left shafts.
Horizontal blade
(R6703)
(R2765)
Center shaft
Left shaft
Center shaft
(R12894)
Right shaft
(R2766)