![Daikin FTXN09KEVJU Service Manual Download Page 24](http://html1.mh-extra.com/html/daikin/ftxn09kevju/ftxn09kevju_service-manual_3342033024.webp)
Outdoor Unit
SiUS041111
16
Printed Circuit Board Connector Wiring Diagram
2. Outdoor Unit
2.1
09/12 Class
Connectors and
Other Parts
PCB(1): Filter PCB
PCB(2): Main PCB
1) S11
Connector for main PCB
2) AC1, AC2, S
Connector for terminal board
3) E1, E2
Terminal for ground
4) HL2, HN2
Connector for main PCB
5) HR1
Connector for reactor
6) FU1
Fuse (3.15 A, 250 V)
7) FU3
Fuse (20 A, 250 V)
8) V2, V3
Varistor
1) S10
Connector for filter PCB
2) S20
Connector for electronic expansion valve coil
3) S40
Connector for overload protector
4) S70
Connector for fan motor
5) S80
Connector for four
-
way valve coil
6) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
7) HL3, HN3
Connector for filter PCB
8) HR2
Connector for reactor
9) U, V, W
Connector for compressor
10)FU2
Fuse (3.15 A, 250 V)
11)LED A
LED for service monitor (green)
12)V1
Varistor