Main Functions
Si18-201
82
Main Functions
1.1.4
Wide Angle Flaps, Louvers and Auto-Swing
For FTK(X)25/35J
Series Only
Outline of the
Action
It can be commanded for J type by means of a user setting to select either any one desired
position among the five-step directions of air flow adjusted on a remote controller, or Auto-
swing.
Although the liquid crystal display of the five-step directions of the air flow is common for the
modes of Cooling·Dry/Heating as illustrated above, in fact the range of the swing angle is
slightly different in every operation mode.
The position a user sets will be selected among the five positions calculated preliminarily and
evenly divided into four partitions which were taken from the upper and lower flap angle’s range
limits of each mode.
When Auto-swing is chosen, the flap swings in the swing range which meets the operation
mode selected.
Others
"
The vertical louver can be adjusted manually. The movable range is 60 degrees for left or
right, and total 120 degrees.
"
A diffuser is not available for J type.
1.1.5
3 Step Flow
For FTX50/60 H
Series Only
(Heat Pump Only)
In the beginning of a heating operation, the unit sends warm air towards the wall behind the unit
to prevent the air from directly blowing on people in the room. After a while, it blows air
downward to warm up the area close to the floor. After the walls and floor become warm, the
unit sends out air according to the set angle and fan speed. (Air flow angle and fan speed set
from remote controller)
1
2
3
4
5
Initial
(RL006)
∗
Fan mode is available for the models of cooling-only.
20˚
45˚
Heating mode
0 degree based on
the horizontal line.
(RL007)
0˚
25˚
Cooling /Dry mode
0 degree based on
the horizontal line.
(RL008)
10˚
45˚
0 degree based on
the horizontal line.
Fan mode
(RL009)
Summary of Contents for FTX25JVEA9
Page 9: ...Si18 201 viii Table of Contents...
Page 71: ...Specifications Si18 201 58 Specifications...
Page 206: ...Si18 201 Remote Controller Operations 193 1 1 2 FVX25 35KZ...
Page 207: ...Remote Controller Si18 201 194 Operations 1 1 3 FTXD25 35KZ...
Page 208: ...Si18 201 Remote Controller Operations 195 1 1 4 FTK FTX50 60H...
Page 209: ...Remote Controller Si18 201 196 Operations 1 1 5 FTKD FTXD50 60 71J...
Page 213: ...Remote Controller Si18 201 200 Operations 1 1 9 FHYC35 50 60 71K Optional Accessory BRC7C612WC...
Page 214: ...Si18 201 Remote Controller Operations 201...
Page 216: ...Si18 201 Remote Controller Operations 203...
Page 217: ...Remote Controller Si18 201 204 Operations...
Page 237: ...Method of Field Set Si18 201 224 Operating Test...
Page 262: ...Si18 201 Troubleshooting SkyAir Indoor Unit Service Diagnosis 249...
Page 393: ...Wiring Diagrams Si18 201 380 Appendix FHYC35 50 60 71KVE9 3D005668C...
Page 394: ...Si18 201 Wiring Diagrams Appendix 381 FHYC35 50 60 71KV1C9...
Page 395: ...Wiring Diagrams Si18 201 382 Appendix FDYM60 03FAV1 FDYM60 03FAVAL C 3D019816D OPTION...
Page 396: ...Si18 201 Wiring Diagrams Appendix 383 FDYM60 03FAV1C...