![Daikin FTX25JVEA9 Service Manual Download Page 360](http://html1.mh-extra.com/html/daikin/ftx25jvea9/ftx25jvea9_service-manual_4183907360.webp)
Si18-201
Installation
Caution Before Operation
347
Hanging bolt (M10 or M8)
Six-sided nut (M10 or M8)
Hanger metal 7
Hanger metal 7
Screws 8
Screws 8
Screws(M5)
(locally procured)
Screws 8
Screws 8
Procedure
(1) Fix the furnished hanger metal 7 with
two screws 8 . (3 locations in total)
(2) After checking with a level that the unit is
level, fix the unit with the furnished wood
screws 7 .
*The tilt of the unit should be 5˚
in front/back and left/right.
Flat washer
Flat washer
15~20
Hanging bolt
Nut
Hanger metal 7
BP unit
Cautions:
•
Once a screw-hole on the main unit has
had a screw hammered in, make sure to
either hammer it again or cover it with
aluminum tape.
(This is to prevent condensation.)
•
Be sure to install the unit with the ceiling-side
up.
•
Do not install near bedrooms. The sound
of refrigerant flowing through the piping
may sometimes be audible.
INSTALLATION OF THE MAIN UNIT
(1) Ceiling-suspended type
(2) Wall-mounted type
Reverse position
Branch pipe side
Printed wiring board
Printed wiring board
As-Shipped condition
After-location is changed
•
This unit has two different installation types:
(1) ceiling-suspended type and (2) wall-mounted type.
•
Choose the proper installation pattern according to
the location of installation.
•
The installation location for printed wiring board can
be changed.
Follow the procedure specified in the
“CONNECTING THE WIRING” section to change
the location. (Refer to
H
mark)
Procedure
(1) Fix the furnished hanger metal 7 with
two screws 8 . (4 locations in total)
(2) Using an insert-hole-in-anchor, hang the
hanging bolt.
(3) Install a hexagon nut and a flat washer
(locally-procured) to the hanging bolt as
shown in the figure in the left, and lift the
main unit to hang on the hanger metal.
(4) After checking with a level that the unit is
level, tighten the hexagon nut.
*The tilt of the unit should be within +5˚
in front/back and left/right.
Ceiling side
NOTES:
CAUTIONS:
2
Summary of Contents for FTX25JVEA9
Page 9: ...Si18 201 viii Table of Contents...
Page 71: ...Specifications Si18 201 58 Specifications...
Page 206: ...Si18 201 Remote Controller Operations 193 1 1 2 FVX25 35KZ...
Page 207: ...Remote Controller Si18 201 194 Operations 1 1 3 FTXD25 35KZ...
Page 208: ...Si18 201 Remote Controller Operations 195 1 1 4 FTK FTX50 60H...
Page 209: ...Remote Controller Si18 201 196 Operations 1 1 5 FTKD FTXD50 60 71J...
Page 213: ...Remote Controller Si18 201 200 Operations 1 1 9 FHYC35 50 60 71K Optional Accessory BRC7C612WC...
Page 214: ...Si18 201 Remote Controller Operations 201...
Page 216: ...Si18 201 Remote Controller Operations 203...
Page 217: ...Remote Controller Si18 201 204 Operations...
Page 237: ...Method of Field Set Si18 201 224 Operating Test...
Page 262: ...Si18 201 Troubleshooting SkyAir Indoor Unit Service Diagnosis 249...
Page 393: ...Wiring Diagrams Si18 201 380 Appendix FHYC35 50 60 71KVE9 3D005668C...
Page 394: ...Si18 201 Wiring Diagrams Appendix 381 FHYC35 50 60 71KV1C9...
Page 395: ...Wiring Diagrams Si18 201 382 Appendix FDYM60 03FAV1 FDYM60 03FAVAL C 3D019816D OPTION...
Page 396: ...Si18 201 Wiring Diagrams Appendix 383 FDYM60 03FAV1C...