Si18-201
Main Functions
Main Functions
95
1.1.29
Air Flow Automatic
(
Auto Fan Speed
)
In cooling operation, if automatic airflow has been selected, the wind flow is determined
according to the room temperature and the temperature setting.
1.1.30
Night Set Mode Function
This mode automatically keeps temperature slightly higher than the temperature setting. In this
way, there is no need to worry about overcooling while sleeping, and it also saves on electricity.
"
Set the OFF timer.
"
The unit will cool the room at the set temperature for 1 hour from when the timer
starts counting.
"
After that, the unit will raise temperature 0.5°C higher than the set temperature and
cool for 30 minutes.
"
After that, the unit will raise temperature another 0.5°C and continue cooling at that
temperature.
"
Setting the OFF timer forcibly changes the airflow adjustment to the tap-L setting.
"
It is possible to change the airflow setting while the OFF timer is in operation.
However, changing the airflow setting cancels the shift-up of the set temperature.
Note:
No higher temperature setting on program Dry or Auto operation.
BLADE ANGLE
UP/DOWN : (AUTOMATIC)
COOLING
DRY
RIGHT/LEFT : (MANUAL)
FLAP
45
˚
45
˚
20
˚
40
˚
20
˚
40
˚
(RL005)
0.5˚C
0.5˚C
30-minutes
60-minutes
Timer start
Set temp.
(M1101)
Summary of Contents for FTX25JVEA9
Page 9: ...Si18 201 viii Table of Contents...
Page 71: ...Specifications Si18 201 58 Specifications...
Page 206: ...Si18 201 Remote Controller Operations 193 1 1 2 FVX25 35KZ...
Page 207: ...Remote Controller Si18 201 194 Operations 1 1 3 FTXD25 35KZ...
Page 208: ...Si18 201 Remote Controller Operations 195 1 1 4 FTK FTX50 60H...
Page 209: ...Remote Controller Si18 201 196 Operations 1 1 5 FTKD FTXD50 60 71J...
Page 213: ...Remote Controller Si18 201 200 Operations 1 1 9 FHYC35 50 60 71K Optional Accessory BRC7C612WC...
Page 214: ...Si18 201 Remote Controller Operations 201...
Page 216: ...Si18 201 Remote Controller Operations 203...
Page 217: ...Remote Controller Si18 201 204 Operations...
Page 237: ...Method of Field Set Si18 201 224 Operating Test...
Page 262: ...Si18 201 Troubleshooting SkyAir Indoor Unit Service Diagnosis 249...
Page 393: ...Wiring Diagrams Si18 201 380 Appendix FHYC35 50 60 71KVE9 3D005668C...
Page 394: ...Si18 201 Wiring Diagrams Appendix 381 FHYC35 50 60 71KV1C9...
Page 395: ...Wiring Diagrams Si18 201 382 Appendix FDYM60 03FAV1 FDYM60 03FAVAL C 3D019816D OPTION...
Page 396: ...Si18 201 Wiring Diagrams Appendix 383 FDYM60 03FAV1C...