![background image](http://html1.mh-extra.com/html/daikin/ftv-a-series/ftv-a-series_engineering-data_2459385018.webp)
16
Installation Guideline
5. Wiring
IMPORTANT:
* The figures shown in the table are for information purpose only. They should be checked
and selected to comply with the local/national codes of regulations. This is also subject to
the type of installation and conductors used.
** The appropriate voltage range should be checked with label data on the unit.
There must be an all pole disconnection
in the supply mains with a contact
separation of at least 3mm.
There must be an all pole disconnection
in the supply mains with a contact
separation of at least 3mm.
Outdoor Unit
Terminal Block
Interconnection
cable
Indoor Unit
Terminal Block
COMP
COMP
N
L
N / L2
L / L1 Power
Supply
Main
Switch
Fuse /
Circuit
Breaker
Power
Supply
Cable
N1
N
Model
Indoor 28/35A 50A 60A
Outdoor 28/35A 50A 60A
Voltage range
**
220-240V/~/50Hz +
Power supply cable size
*
mm
2
Number of conductors
1.5
3
2.5
3
2.5
3
Interconnection cable size
*
mm
2
Number of conductors
1.5
3
2.5
3
2.5
3
Recommended fuse /circuit breaker rating A
16
20
20
Outdoor Unit
Terminal Block
Indoor Unit
Terminal Block
N
L
N / L2
L / L1
Power
Supply
Main Switch
Fuse / Circuit
Breaker
Power Supply Cable
Model
Indoor
28/35P
50/60P
Outdoor
28/35F
50/60C
Voltage range**
220-240V/~/50Hz +
Power supply cable size*
mm
2
Number of conductors
1.5
3
2.5
3
Interconnection cable size*
mm
2
Number of conductors
1.5
3
2.5
3
Recommended fuse /circuit breaker rating A
16
20
COMP
N1
N
COMP
Cooling Unit (single phase)
Interconnection
cable
Summary of Contents for FTV-A Series
Page 1: ...TM FTV 1020 F Split Unit Air Conditioner Wall Mounted FTV A P PS Series Cooling Only 50Hz...
Page 2: ......
Page 30: ...28 Dimensions Model FTV85PS Note Dimension in mm FOR ILLUSTRATIVE PURPOSES ONLY...
Page 33: ...31 Dimensions Model RC85A Note Dimension in mm FOR ILLUSTRATIVE PURPOSES ONLY...
Page 35: ...33 Wiring Diagram Model RV35A Model RV50 60A R08024149386 3P548018 1...
Page 37: ...35 Wiring Diagram Model FTV50 60P Outdoor Unit Model RV50 60C R08024149860A R08024145839...
Page 56: ...54 Capacity Tables FTV28P RV28F FTV35P RV35F...