18
Installation Guideline
Outdoor Installation Guideline
Wall facing one side
Walls facing two sides
Walls facing three sides
More than 50
More than 100
1200 or
less
Side view
More than 50
More than 150
Top view
More than 300
More than
100
More than 50
Top view
More than 50
More than 150
Wall facing one side
Side view
More than 100
More than 350
1200 or
less
Walls facing two sides
Walls facing three sides
Top view
More than
100
More than 50
More than 50
More than 350
Top view
More than 50
More than 100
More than 350
(Unit: mm)
Special Precautions When Dealing With R32 Unit
*
Calculation based on Installation Height of 1.8m
*
Max. Allowable Length (L),m for:-
FTV28/35-RV28/35 : 25
FTV50/60-RV50/60 : 30
FTV85PS-RC85A : 50
1. Installing Outdoor Unit
• Where a wall or other obstacle is in the path of outdoor unit’s intake or exhaust airflow, follow the installation
guidelines below.
• For any of the below installation patterns, the wall height on the exhaust side should be 1200mm or less.
• Installation of pipe work shall be kept to a minimum and pipe work shall be protected from physical damage and
shall not be installed in an unventilated space;
• Reusable mechanical connectors and flare joints shall be accessible for maintenance purposes;
RV28/35
RV50/60, RC85
Model
R32 charge, kg for 7.5m
piping
Minimum floor area, Xm
2
(based on 7.5m piping)
R32 charge, kg for max
allowable pipe length
*
Minimum floor area, Xm
2
(based on max allowable
pipe length
*
)
FTV28A - RV28A
0.50 0.24 0.71 0.48
0.68 0.44 0.98 0.91
1.10 1.15 1.48 2.10
FTV35A - RV35A
FTV50A - RV50A
FTV60A - RV60A
1.10
1.15
1.48
2.10
Model
R32 charge, kg for 7.5m
piping
Minimum floor area, Xm
2
(based on 7.5m piping)
R32 charge, kg for max
allowable pipe length
*
Minimum floor area, Xm
2
(based on max allowable
pipe length
*
)
FTV28P - RV28F
0.55 0.29 0.85 0.68
0.76 0.55 1.06 1.07
0.75 0.54 1.13 1.22
FTV35P - RV35F
FTV50P - RV50C
FTV60P - RV60C
0.70
0.47
1.08
1.12
Model
R32 charge, kg for 7.5m
piping
Minimum floor area, Xm
2
(based on 7.5m piping)
R32 charge, kg for max
allowable pipe length
*
Minimum floor area, Xm
2
(based on max allowable
pipe length
*
)
FTV85PS - RC85A
1.6 2.44 3.30 10.38
Summary of Contents for FTV-A Series
Page 1: ...TM FTV 1020 F Split Unit Air Conditioner Wall Mounted FTV A P PS Series Cooling Only 50Hz...
Page 2: ......
Page 30: ...28 Dimensions Model FTV85PS Note Dimension in mm FOR ILLUSTRATIVE PURPOSES ONLY...
Page 33: ...31 Dimensions Model RC85A Note Dimension in mm FOR ILLUSTRATIVE PURPOSES ONLY...
Page 35: ...33 Wiring Diagram Model RV35A Model RV50 60A R08024149386 3P548018 1...
Page 37: ...35 Wiring Diagram Model FTV50 60P Outdoor Unit Model RV50 60C R08024149860A R08024145839...
Page 56: ...54 Capacity Tables FTV28P RV28F FTV35P RV35F...
Page 68: ...66 Sound Level FTV85PS...