![Daikin FTV-A Series Engineering Data Download Page 65](http://html1.mh-extra.com/html/daikin/ftv-a-series/ftv-a-series_engineering-data_2459385065.webp)
63
Sound Level
Sound Pressure Level
Model
Speed
1/1 Octave Sound Pressure (dB, ref 20µPa)
Overall
(dBA)
Noise
Criteria
125Hz 250Hz 500Hz
1kHz
2kHz
4kHz
8kHz
FTV28P
High
30
34
35
33
29
21
8
37
32
Med
27
31
32
28
23
14
6
33
26
Low
24
26
27
22
15
7
7
27
21
Quiet
23
24
25
20
13
6
5
25
NA
FTV35P
High
33
36
37
35
32
24
12
39
34
Med
31
33
34
30
26
17
11
35
29
Low
30
28
29
24
19
11
10
29
23
Quiet
29
27
28
23
18
11
10
28
22
FTV50P
High
40
42
42
42
39
32
20
42
37
Med
37
39
39
39
36
27
19
39
34
Low
34
37
37
36
32
24
18
36
32
Quiet
31
35
35
33
29
22
18
35
30
FTV60P
High
40
42
42
42
39
32
20
46
43
Med
37
39
39
39
36
27
19
43
39
Low
34
37
37
36
32
24
18
39
35
Quiet
31
35
35
33
29
22
18
37
33
FTV85PS
High
50
48
46
47
44
39
31
51
46
Med
45
46
42
42
38
32
23
46
41
Low
43
43
38
39
34
27
17
42
38
Quiet
41
41
35
35
29
23
15
39
34
Summary of Contents for FTV-A Series
Page 1: ...TM FTV 1020 F Split Unit Air Conditioner Wall Mounted FTV A P PS Series Cooling Only 50Hz...
Page 2: ......
Page 30: ...28 Dimensions Model FTV85PS Note Dimension in mm FOR ILLUSTRATIVE PURPOSES ONLY...
Page 33: ...31 Dimensions Model RC85A Note Dimension in mm FOR ILLUSTRATIVE PURPOSES ONLY...
Page 35: ...33 Wiring Diagram Model RV35A Model RV50 60A R08024149386 3P548018 1...
Page 37: ...35 Wiring Diagram Model FTV50 60P Outdoor Unit Model RV50 60C R08024149860A R08024145839...
Page 56: ...54 Capacity Tables FTV28P RV28F FTV35P RV35F...
Page 68: ...66 Sound Level FTV85PS...