Installation Guideline
6. Wiring
WARNING
• Do not turn ON the safety breaker until all work is
completed.
1) Strip the insulation from the wire (20 mm).
2) Connect the connection wires between the indoor
and outdoor units
so that the terminal numbers
match
. Tighten the terminal screws securely. We
recommend a flathead screwdriver be used to
tighten the screws.
Observe the notes mentioned below when wiring to the power supply
terminal board.
Precautions to be taken for power supply wiring.
(Use a round crimp-style terminal for connection to the power
supply terminal board. In case it cannot be used due to
unavoidable reasons, be sure to observe the following instruction.)
Round crimp-style
terminal
Stranded Wire
CAUTION
When connecting the connection wires to the terminal board using a single core wire, be sure to perform curling.
Problems with the work may cause heat and fires.
Stripping wire at terminal block
Strip wire end to
this point.
Good
Wrong
Excessive strip length
may cause electrical
shock or leakage.
3) Pull the wire and make sure that it does not disconnect. Then fix the wire in place with a wire stop.
Terminal block
Earth screw
COMP
N
Summary of Contents for FTV-A Series
Page 1: ...TM FTV 1020 F Split Unit Air Conditioner Wall Mounted FTV A P PS Series Cooling Only 50Hz...
Page 2: ......
Page 30: ...28 Dimensions Model FTV85PS Note Dimension in mm FOR ILLUSTRATIVE PURPOSES ONLY...
Page 33: ...31 Dimensions Model RC85A Note Dimension in mm FOR ILLUSTRATIVE PURPOSES ONLY...
Page 35: ...33 Wiring Diagram Model RV35A Model RV50 60A R08024149386 3P548018 1...
Page 37: ...35 Wiring Diagram Model FTV50 60P Outdoor Unit Model RV50 60C R08024149860A R08024145839...
Page 56: ...54 Capacity Tables FTV28P RV28F FTV35P RV35F...
Page 68: ...66 Sound Level FTV85PS...