Main Functions
SiENBE04-507A
50
Function and Control
1.4
Programme Dry Function
Programme dry function removes humidity while preventing the room temperature from
lowering.
Since the microcomputer controls both the temperature and air flow volume, the temperature
adjustment and fan adjustment buttons are inoperable in this mode.
In Case of
Inverter Units
The microcomputer automatically sets the temperature and fan settings. The difference
between the room temperature at startup and the temperature set by the microcomputer is
divided into two zones. Then, the unit operates in the dry mode with an appropriate capacity for
each zone to maintain the temperature and humidity at a comfortable level.
Room temperature at
startup
Temperature (ON point)
at which operation starts
Frequency switching
point
Temperature difference
for operation stop
24
ş
C Room temperature at
startup
0.5
ş
C
1.5
ş
C
18
ş
C
18
ş
C
1.0
ş
C
17
ş
C
—
5 min
5 min
LHz indicates low frequency. Item marked with varies depending on models.
ON point
OFF point
Compressor
control
Stop
Indoor unit fan
Extra-low air flow
Stop
Stop
Stop
Stop
Stop
Extra-low air flow
Frequency
switching
point
Low air flow
(R1359)
Low air flow
0.5°C
*
55Hz
*
55Hz
LHz
LHz
LHz
Summary of Contents for FTKS20D2VMWL
Page 10: ...SiENBE04 507A List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Page 85: ...Control Specification SiENBE04 507A 76 Function and Control...
Page 159: ...Check SiENBE04 507A 150 Service Diagnosis...
Page 215: ...Others SiENBE04 507A 206 Others...
Page 221: ...Wiring Diagrams SiENBE04 507A 212 Appendix...
Page 225: ...SiENBE04 507A iv Index...