![Daikin FTKS20D2VMWL Service Manual Download Page 49](http://html1.mh-extra.com/html/daikin/ftks20d2vmwl/ftks20d2vmwl_service-manual_2459361049.webp)
Printed Circuit Board Connector Wiring Diagram
SiENBE04-507A
40
Printed Circuit Board Connector Wiring Diagram
1. Printed Circuit Board Connector Wiring Diagram
1.1
Indoor Unit
Connectors
Note:
Other designations
1) S1
Connector for fan motor
2) S6
Connector for swing motor (horizontal blades)
3) S21
Connector for centralized control (HA)
4) S26
Connector for display PCB
5) S27, S29, S36 Connector for control PCB
6) S28
Connector for signal receiver PCB
7) S32
Connector for heat exchanger thermistor
8) S35
Connector for INTELLIGENT EYE sensor PCB
1) V1
Varistor
2) JA
Address setting jumper
JB
Fan speed setting when compressor is OFF on thermostat
JC
Power failure recovery function (auto-restart)
∗
Refer to page 205 for detail.
3) SW1
Forced operation ON / OFF switch
4) LED1
LED for operation (green)
5) LED2
LED for timer (yellow)
6) LED3
LED for INTELLIGENT EYE (green)
7) LED A
LED for service monitor (green)
8) FU1
Fuse (3.15A)
9) RTH1
Room temperature thermistor