![Daikin FTKS20D2VMWL Service Manual Download Page 162](http://html1.mh-extra.com/html/daikin/ftks20d2vmwl/ftks20d2vmwl_service-manual_2459361162.webp)
SiENBE04-507A
Indoor Unit
Removal Procedure
153
3. Removing the titanium
apatite photocatalytic air-
purifying filter
1
The titanium apatite
photocatalytic air-
purifying filter is
attached to the back of
the air filter.
The titanium apatite
photocatalytic air-purifying
filter is not marked for
difference between the right
and left sides.
2
3
Remove the titanium
apatite photocatalytic
air-purifying filter frame
by bending the air filter
and unfastening the
projections from the air
filter frame.
Remove the titanium
apatite photocatalytic
air-purifying filter from
its frame (at 5 positions)
by bending it.
Step
Procedure
Points
(R4310)
Projections
(R4309)
Titanium apatite
photocatalytic
air-purifying filter
Air filter
(R4311)