![Daikin FTKS20D2VMWL Service Manual Download Page 34](http://html1.mh-extra.com/html/daikin/ftks20d2vmwl/ftks20d2vmwl_service-manual_2459361034.webp)
SiENBE04-507A
Specifications
Specifications
25
50Hz 230V
Note:
MAX. interunit piping length: 20m
MAX. interunit height difference: 15m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Models
Indoor Units
FTXS25DVMW(9)
FTXS25DVMW(9)
Outdoor Units
RXS25DVMB
RXS25D2VMB
Cooling
Heating
Cooling
Heating
Capacity
Rated (Min.~Max.)
kW
2.5 (1.3~3.0)
3.4 (1.3~4.5)
2.5 (1.3~3.0)
3.4 (1.3~4.5)
Btu/h
8,550 (4,450~10,250)
11,600 (4,450~15,350)
8,550 (4,450~10,250)
11,600 (4,450~15,350)
kcal/h
2,150 (1,120~2,580)
2,920 (1,120~3,870)
2,150 (1,120~2,580)
2,920 (1,120~3,870)
Moisture Removal
L/h
1.2
—
1.2
—
Running Current (Rated)
A
3.8
4.3
3.8
4.3
Power Consumption
Rated (Min.~Max.)
W
685 (300~960)
920 (290~1,430)
685 (300~960)
920 (290~1,430)
Power Factor
%
78.4
93.0
78.4
93.0
COP
Rated (Min.~Max.)
W/W
3.65 (4.33~3.13)
3.70 (4.48~3.15)
3.65 (4.33~3.13)
3.70 (4.48~3.15)
Piping
Connections
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
φ
18.0
φ
18.0
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Indoor Units
FTXS25DVMW(9)
FTXS25DVMW(9)
Front Panel Color
White
White
Air Flow Rate m
ł
/min
(cfm)
H
8.7 (307)
9.4 (332)
8.7 (307)
9.4 (332)
M
6.7 (237)
7.6 (268)
6.7 (237)
7.6 (268)
L
4.7 (166)
5.8 (205)
4.7 (166)
5.8 (205)
SL
3.9 (138)
5.0 (177)
3.9 (138)
5.0 (177)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
40
40
Speed
Steps
5 Steps, Silent, Auto
5 Steps, Silent, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.16
0.16
0.16
0.16
Power Consumption (Rated)
W
35
35
35
35
Power Factor
%
95.1
95.1
95.1
95.1
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
283×800×195
283×800×195
Packaged Dimensions (H×W×D)
mm
265×855×340
265×855×340
Weight
kg
9
9
Gross Weight
kg
12
12
Operation
Sound
H/L/SL
dBA
38 / 25 / 22
38 / 28 / 25
38 / 25 / 22
38 / 28 / 25
Sound Power H
dBA
56
56
56
56
Outdoor Units
RXS25DVMB
RXS25D2VMB
Casing Color
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
1YC23NXD#A
1YC23NXD#A
Motor Output
W
600
600
Refrigerant
Oil
Type
FVC50K
FVC50K
Charge
L
0.375
0.375
Refrigerant
Type
R-410A
R-410A
Charge
kg
0.8
0.8
Air Flow Rate m
ł
/min (cfm)
H
36.2 (1,278)
32.6 (1,151)
36.2 (1,278)
32.6 (1,151)
L
25.7 (907)
30.6 (1,080)
25.7 (907)
30.6 (1,080)
Fan
Type
Propeller
Propeller
Motor Output
W
50
50
Running Current (Rated)
A
3.64
4.14
3.64
4.14
Power Consumption (Rated)
W
650
885
650
885
Power Factor
%
77.6
92.9
77.6
92.9
Starting Current
A
4.3
4.3
Dimensions (H×W×D)
mm
550×765×285
550×765×285
Packaged Dimensions (H×W×D)
mm
589×882×363
589×882×363
Weight
kg
30
30
Gross Weight
kg
35
35
Operation
Sound
H/L
dBA
46 / 43
47 / 44
46 / 43
47 / 44
Sound Power H
dBA
61
62
61
62
Drawing No.
3D049112A
3D050849
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m
ł
/min×35.3
Cooling
Heating
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m
Summary of Contents for FTKS20D2VMWL
Page 10: ...SiENBE04 507A List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Page 85: ...Control Specification SiENBE04 507A 76 Function and Control...
Page 159: ...Check SiENBE04 507A 150 Service Diagnosis...
Page 215: ...Others SiENBE04 507A 206 Others...
Page 221: ...Wiring Diagrams SiENBE04 507A 212 Appendix...
Page 225: ...SiENBE04 507A iv Index...