![Daikin FTKS20D2VMWL Service Manual Download Page 106](http://html1.mh-extra.com/html/daikin/ftks20d2vmwl/ftks20d2vmwl_service-manual_2459361106.webp)
SiENBE04-507A
Instruction
System Configuration
97
ATTENTION
To use ON TIMER operation
•
Check that the clock is correct. If not, set the
clock to the present time. (page 84)
1. Press “ON TIMER button”.
6:00
is displayed.
blinks.
2. Press “TIMER Setting button” until the time
setting reaches the point you like.
•
Every pressing of either button increases or
decreases the time setting by 10 minutes.
Holding down either button changes the
setting rapidly.
3. Press “ON TIMER button” again.
•
The TIMER lamp lights up.
To cancel ON TIMER operation
4. Press “CANCEL button”.
•
The TIMER lamp goes off.
To combine ON TIMER and OFF TIMER
•
A sample setting for combining the two timers is
shown below.
TEMP
ON/OFF
POWERFUL
MODE
FAN
SWING
SILENT
SENSOR
ECONO
COMFORT
TIMER
ON
CANCEL
OFF
2
1, 3
4
Displa
y
(Example)
Present time: 11:00 PM
(The unit operating)
OFF TIMER at 0:00 a.m.
ON TIMER at 7:00 a.m.
Combined
In the following cases, set the timer again.
•
After a breaker has turned OFF.
•
After a power failure.
•
After replacing batteries in the remote control.
Summary of Contents for FTKS20D2VMWL
Page 10: ...SiENBE04 507A List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Page 85: ...Control Specification SiENBE04 507A 76 Function and Control...
Page 159: ...Check SiENBE04 507A 150 Service Diagnosis...
Page 215: ...Others SiENBE04 507A 206 Others...
Page 221: ...Wiring Diagrams SiENBE04 507A 212 Appendix...
Page 225: ...SiENBE04 507A iv Index...