CAUTION
During the installation of the bottom plate of the wired controller, pay attention to the direction of the bottom
plate. The plate’s side with two notches must be at the lower position, otherwise
,
the panel of the wired
controller cannot be correctly installed.
Electric box cover
Wire clamp
Control wire
Cable-cross loop
Communication wire
PCB
sketch map for indoor unit
communication wire
1# metallic pipe
1
3
2
4
Fig.8.16 Surface Mounting
Fig.8.17 Concealed mounting
Fig.8.18 Sketch for Installation of Wired
of Cable
of Cable
Controller
No.
1
2
3
4
Description Wall
Surface
Bottom Plate of
Wire
d
Controller
Screw M4X10
Front panel of
Wired C
ontroller
8.13 Connection of Signal Line of Wired Controller
1. Open the cover of the electric box of the indoor unit.
2. Pull the signal cable of the wire
d
controller through the rubber ring.
3. Plug the signal line of the wire
d
controller onto the 4-bit pin socket at the circuit board of the indoor unit.
(CN10 of the wire
d
controller connect with CN3 of the indoor unit)
4. Use cable fastener to bundle and fix the signal cable of the wire
d
controller.
CAUTION
1. The communication distance between the main board and the wire
d
controller is 8m.
2. The wire
d
controller shall not be installed in a place where there is water drop or large amount of water
vapor.
English