Appendix:
Air conditioner nominal working condition and working range:
Test condition
Indoor side
Outdoor side
DB(°C) WB(°C) DB(°C) WB(°C)
Nominal
cooling
27 19 35 24
Nominal
heating
20 – 7 6
Rated
cooling
32 23 52 31
Low temp. cooling
21
15
18
–
Rated
heating
27 – 24 18
Low temp. heating
20
–
–7
–8
Note:
1. The design of this unit conforms to the requirements of ISO13253 standard.
2. The air volume is measured at the relevant standard external static pressure.
3. Cooling (heating) capacity stated above is measured under nominal working conditions corresponding
to standard external static pressure. The parameters are subject to change with the improvement of
products, in which case the values on nameplate shall prevail.
WARNING
• This appliance is not intended for use by persons (including children) with reduced physical sensory or
capabilities, or l
of experience and knowledge, unless they have been given supervision on instruction
concerning use of appliance by a person responsible for their safety.
ack
• Children should be supervised to ensure that they do not play with the appliance.
This product must not be disposed together with the
domestic waste. This product has to be disposed at an
authorized place for recycling of electrical and electronic
appliances.
English
41