IX SPECIFICATIONS
INDOOR UNIT
FDM24PEV1K
FDM30PEV1K
FDM36PEV1K
FDM42PEV1K
FDM48PEV1K
OUTDOOR UNIT
R24PEV1K
R30PEV1K
R36PEY1K
R42PEY1K
R48PEY1K
RA
TED V
O
LT
A
G
E
V
220-240
220-240
380-415
380-415
380-415
RA
TED FREQ
UENCY
Hz
50
50
50
50
50
COOLING(T1)
RA
TED PO
WER INPUT
kW
2.50
2.92
3.90
4.60
5.40
RA
TED CURRENT INPUT
A
11.9
13.5
7.1
8.9
10.4
CAP
A
CITY
kW
6.8
7.7
9.7
11.3
13.0
Btu/h
23200
26300
33000
38600
44400
EER
(Btu/h)/W
9.28
9.01
8.46
8.39
8.22
REFRIGERANT
R22
R22
R22
R22
R22
MASS OF REFRIGERANT CHARGE
kg
2.
50
3
.4
0
3.60
3.05
5.0
0
WEIGHT OF INDOOR UNIT
kg
36
36
53
5
3
5
5
WEIGHT OF OUTDOOR UNIT
kg
66
73
89
94
107
COUNTR
Y OF ORIGIN
MADE IN CHINA
INDOOR UNIT
FD
YM24PEV1K
FD
YM30PEV1K
FD
YM36PEV1K
FD
YM42PEV1K
FD
YM48PEV1K
OUTDOOR UNIT
R
Y24PEV1K
R
Y30PEV1K
R
Y36PEY1K
R
Y42PEY1K
R
Y48PEY
1
K
RA
TED V
O
LT
A
G
E
V
220-240
220-240
380-415
380-415
380-415
RA
TED FREQ
UENCY
Hz
50
50
50
50
50
COOLING(T1)
RA
TED PO
WER INPUT
kW
2.50
2.95
3.90
4.80
5.50
RA
TED CURRENT INPUT
A
11.9
14.5
7.2
9.3
10.2
CAP
A
CITY
kW
6.8
7.7
9.7
11.3
13.0
Btu/h
23200
26300
33000
38600
44400
EER
(Btu/h)/W
9.28
8.92
8.46
8.04
8.07
HEA
TING
RA
TED PO
WER INPUT
kW
2.45
3.30
3.45
4.15
4.75
RA
TED CURRENT INPUT
A
12.4
16.8
6.7
8.1
9.1
CAP
A
CITY
kW
7.5
9.4
12.0
13.5
14.1
Btu/h
25500
32100
41000
46100
48200
COP
W/W
3.06
2.85
3.48
3.25
2.97
REFRIGERANT
R22
R22
R22
R22
R22
MASS OF REFRIGERANT CHARGE
kg
2.
50
3
.4
03
.6
03
.
05
5
.
0
0
WEIGHT OF INDOOR UNIT
kg
36
36
53
5
3
5
5
WEIGHT OF OUTDOOR UNIT
kg
67
74
90
96
108
COUNTR
Y OF ORIGIN
MADE IN CHINA
English
42