10
|
Configuration
Installer reference guide
126
ERLA EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1B – 2021.10
The setting
Emitter type
can compensate for a slow or a quick heating/cooling
system during the heat up/cool down cycle. In room thermostat control, the
emitter type influences the maximum modulation of the desired leaving water
temperature, and the possibility for usage of the automatic cooling/heating
changeover based on the indoor ambient temperature.
It is important to set the emitter type correctly and in accordance with your system
layout. The target delta T for the main zone depends on it.
#
Code
Description
[A.3.1.1.7]
[2-0C]
Emitter type
▪
0:
Underfloor heat
▪
1:
Fancoil unit
▪
2:
Radiator
10.2.5 Domestic hot water control
#
Code
Description
[A.4.1]
[6-0D]
Domestic hot water
Type
:
▪
0 (
Reheat only
): Only reheat operation is
allowed.
▪
1 (
Reheat + sched.
): Same as 2, but
between the scheduled heatup cycles, reheat
operation is allowed.
▪
2 (
Scheduled only
): The domestic hot water
tank can ONLY be heated according to a
schedule.
[A.4.5]
[6-0E]
The maximum temperature that users can select
for the domestic hot water. You can use this
setting to limit the temperature at the hot water
taps.
INFORMATION
There is a risk of space heating (or cooling) capacity shortage/comfort problem when
selecting [6‑0D]=0 ([A.4.1] Domestic hot water
Type
=
Reheat only
).
In case of frequent domestic hot water operation, frequent and long space heating
interruption will happen.
Maximum DHW temperature setpoint
The maximum temperature that users can select for the domestic hot water. You
can use this setting to limit the temperatures at the hot water taps.
INFORMATION
During disinfection of the domestic hot water tank, the DHW temperature can
exceed this maximum temperature.
INFORMATION
Limit the maximum hot water temperature according to the applicable legislation.