Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.8
[2-09]
R/W
-5~5°C, step: 0,5°C
0°C
A.8
[2-0A]
R/W
-5~5°C, step: 0,5°C
0°C
A.8
[2-0B]
R/W
-5~5°C, step: 0,5°C
0°C
A.8
[2-0C]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
A.8
[2-0D]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
A.8
[3-00]
R/W
0: No
1: Yes
A.8
[3-01]
0
A.8
[3-02]
1
A.8
[3-03]
4
A.8
[3-04]
2
A.8
[3-05]
1
A.8
[3-06]
R/W
18~30°C, step: 0,5°C
30°C
A.8
[3-07]
R/W
12~18°C, step: 0,5°C
12°C
A.8
[3-08]
R/W
25~35°C, step: 0,5°C
35°C
A.8
[3-09]
R/W
15~25°C, step: 0,5°C
15°C
A.8
[4-00]
R/W
0: Disabled
1: Enabled
2: Only DHW
A.8
[4-01]
R/W
0: None
1:
-
2: BUH
A.8
[4-02]
R/W
14~35°C, step: 1°C
22°C
A.8
[4-03]
3
A.8
[4-04]
R/O
0: intermittent pump operation
1: Continuous pump operation
2: OFF
A.8
[4-05]
0
A.8
[4-06]
R/W
0: Manual
1: Automatic
A.8
[4-08]
R/W
0: No limitation
1: Continuous
2: Digital inputs
A.8
[4-09]
R/W
0: Current
1: Power
A.8
[4-0A]
0
A.8
[4-0B]
R/W
1~10°C, step: 0,5°C
1°C
A.8
[4-0D]
R/W
1~10°C, step: 0,5°C
3°C
A.8
[5-00]
R/W
0: Allowed
1: Not allowed
A.8
[5-01]
R/W
-15~35°C, step: 1°C
0°C
A.8
[5-02]
R/W
0: Disabled
1: Enabled
A.8
[5-03]
R/W
-15~35°C, step: 1°C
0°C
A.8
[5-04]
R/W
0~20°C, step: 1°C
10°C
A.8
[5-05]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-06]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-07]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-08]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-09]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0A]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0B]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0C]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0D]
0
A.8
[5-0E]
1
A.8
[6-00]
R/W
2~40°C, step: 1°C
25°C
A.8
[6-01]
R/W
0~10°C, step: 1°C
2°C
A.8
[6-02]
0
A.8
[6-03]
0
A.8
[6-04]
0
A.8
[6-05]
0
A.8
[6-06]
0
A.8
[6-07]
0
A.8
[6-08]
R/W
2~20°C, step: 1°C
10°C
A.8
[6-09]
0
A.8
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
60°C
A.8
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
50°C
A.8
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
A.8
[6-0D]
R/W
0: Reheat only
1: sched.
2: Scheduled only
Is the pump allowed during pipe freeze prevention?
--
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
What is the desired reheat temperature?
What is the desired DHW production type?
--
--
--
--
--
What is the hysteresis to be used in reheat mode?
What is the requested limit for DI4?
--
--
The temperature difference determining the heat pump ON temperature.
The temperature difference determining the heat pump OFF temperature.
--
What is the requested limit for DI2?
What is the requested limit for DI3?
What is the requested limit for DI4?
What is the requested limit for DI1?
What is the requested limit for DI2?
What is the requested limit for DI3?
Is backup heater operation allowed above equilibrium temperature during space
heating operation?
What is the equilibrium temperature for the building?
Space heating priority.
Space heating priority temperature.
Set point correction for domestic hot water temperature.
What is the requested limit for DI1?
Emergency
Which power limitation mode is required on the system?
Which power limitation type is required?
--
Automatic cooling/heating changeover hysteresis.
Automatic cooling/heating changeover offset.
What is the minimum desired room temperature in cooling?
What is the BUH operation mode?
Which electric heater has priority?
Below which outdoor temperature is heating allowed?
--
--
--
--
--
What is the maximum desired room temperature in heating?
What is the mimimum desired room temperature in heating?
What is the maximum desired room temperature in cooling?
What is the required offset on the measured outdoor temp.?
What emitter type is connected to the main LWT zone
What emitter type is connected to the additional LWT zone?
Is auto restart of the unit allowed?
--
--
Adjust the offset on the measured room temperature
Adjust the offset on the measured room temperature
(*1) Only applicable for models where cooling is possible
(*2) EHFZ03S18DJ3V