10
|
Configuration
Installer reference guide
115
ERLA EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1B – 2021.10
Confirm layout
Please confirm the system
layout. The system will
restart and will be ready for
first startup.
OK
Cancel
Confirm
Adjust
Result:
The user interface reinitializes.
5
Proceed with the configuration of the system. When done, confirm the
configuration settings.
Result:
The screen shortly turns OFF and
Busy
is displayed for several seconds.
10.2 Basic configuration
10.2.1 Quick wizard: Language / time and date
#
Code
Description
[A.1]
N/A
Language
[1]
N/A
Time and date
10.2.2 Quick wizard: Standard
Space heating/cooling settings
The system can heat up or cool down a space. Depending on the type of
application, the space heating/cooling settings must be made accordingly.
Space heating/cooling: Unit control method
#
Code
Description
[A.2.1.7]
[C-07]
Unit control method
▪
0 (
LWT control
)
▪
1 (
Ext RT control
)
▪
2 (
RT control
)
LWT control
:
Unit operation is decided based on the leaving water temperature regardless the
actual room temperature and/or heating or cooling demand of the room.
Ext RT control
:
Unit operation is decided by the external thermostat or equivalent (e.g. heat pump
convector).
RT control
:
Unit operation is decided based on the ambient temperature of the user interface.
Space heating/cooling: User interface location
#
Code
Description
[A.2.1.B]
N/A
User interface location
▪
0 (
At unit
)
▪
1 (
In room
)