08 + ERLQ004~008
Daikin Altherma - Low Temperature Split
4P313774-1 – 2012.05
Installer reference guide
74
15 Technical data
15.2
Center of gravity
15.2.1 Center of gravity: Outdoor unit
15.3
Components
15.3.1 Components: Outdoor unit
15.3.2 Components: Switch box (outdoor unit)
4TW60819-1
UNIT
a
Switch box main PCB (inverter and control PCB)
b
Terminal communication and power supply
c
Service PCB
d
4-way valve
e
Electronic expansion valve (main)
f
Accumulator
g
Compressor
h
Liquid stop valve
i
Gas stop valve
j
Service port
k
Fan motor
l
Heat exchanger
b
c
d
e
f
j
h
i
g
a
l
k
a
Service PCB
b
Terminal communication cable
c
Terminal power supply cable
d
Earth connection
e
Wire clamp
a
c
d
e
b