Installer reference guide
83
08 + ERLQ004~008
Daikin Altherma - Low Temperature Split
4P313774-1 – 2012.05
15 Technical data
I
I
F2B
4
2
E2H
E2H
E2H
E1H
E1H
E1H
E2H
E2H
E2H
E1H
E1H
E1H
F1T
F1T
F1T
F1T
F1T
F1T
K2M
2
1
6
5
4
3
K1M
2
1
6
5
4
3
F1T
F1T
F1T
F1T
F1T
F1T
K2M
2
1
6
5
4
3
K1M
2
1
6
5
4
3
X7M
4
8
7
6
5
3
2
1
X6M
X7M
4
8
7
6
5
3
2
1
X6M
X7M
4
8
7
6
5
3
2
1
X6M
X7M
4
8
7
6
5
3
2
1
X6M
E2H
E2H
E2H
E1H
E1H
E1H
E2H
E2H
E2H
E1H
E1H
Q1DI
I
I
I
I
F1B
8
7
6
5
4
3
2
1
E1H
F1T
F1T
F1T
F1T
F1T
F1T
14
13
K5M
2
1
6
5
4
3
K2M
2
1
6
5
4
3
K1M
2
1
6
5
4
3
I
I
I
I
F1B
8
7
6
5
4
3
2
1
Q1DI
14
13
K5M
2
1
6
5
4
3
I
I
F1B
8
7
6
5
4
3
2
1
Q1DI
14
13
K5M
2
1
6
5
4
3
Q1DI
F1T
F1T
F1T
F1T
F1T
F1T
I
I
I
I
F1B
8
7
6
5
4
3
2
1
14
13
K5M
2
1
6
5
4
3
K2M
2
1
6
5
4
3
K1M
2
1
6
5
4
3
N
L2
L3
L1
L2
L3
L1
Q2L
1
2
3
1
K3M
2
1
4
3
E4H
X6M
2
1
X4M 1
2
Q2L
1
2
4
3
Q2L
1
2
4
3
Q2L
1
2
E4H
E4H
E4H
X9M
2
1
X6M
2
1
X9M
2
1
2
2
2
2
7
21
22
Q1L
11
12
F2B
3
1
E3H
Q1DI
F1T
K1M
2
1
4
3
11
L2
L1
11
N
L
4D077028 page 2
I
I
4
2
Q1DI
N
L
7
7
7
N
L
N
L
I
I
BRN
RED
GRY
BLK
BRN
RED
GRY
BLK
BRN
RED
GRY
BLK
BRN
RED
GRY
BLK
1N~, 50 Hz
230 V AC
1N~, 50 Hz
230 V AC
1N~, 50 Hz
230 V AC
3N~, 50 Hz
400 V AC
3~, 50 Hz
230 V AC
2~, 50 Hz
400 V AC
1N~, 50 Hz
230 V AC
only for *KHW*Z2
only for *KHW*V3
only for *KHWS*Z2
only for *KHWE*Z2
domestic hot water tank
domestic hot water tank
only for *KHWE*V3
domestic hot water tank
for 6T1 (3~, 230 V, 6 kW)
for 6WN (3N~, 400 V, 6 kW) and 9WN (3N~, 400 V, 9 kW)
for 6V3 (1N~, 230 V, 6 kW)
for 3V3 (1N~, 230 V, 3 kW)
only for *9W
only for *3V
only for *KHWS*V3
domestic hot water tank
4D077028 page 3
A4P.YC
A4P.Y2
A4P.Y2
X2M.29
S6S
S7S
S8S
S9S
S3S
BSK
S1S
S2S
B1L
X2M.14
X2M.9
X2M.14
X2M.9
X2M.13
-t°
R5T
-t°
R6T
2
KHR
KHUR
KCR
KFR
-t°
R1T
-t°
R1T
2
X18A:1
2
X22A:1
X85A:1
2
3 4
5 6
-t°
R1T
F1U
F2U
3
CN1:1
6
5
4
3
2
CN2:1
X80A:1 2
7
8
4
X4A:1
2
3
X33A:1
3
4
6
5
3
4
5
6
7
8
9
12
11
10
X40A:1
2
3
4
6
5
-t°
R5T
2
X9A:1
-t°
R4T
X7A:1
X8A:1
-t°
R2T
2
X5A:1
2
-t°
R3T
2
2
X6A:1
10
10
A1P
PHC1
Y1
Y2
YC
Y4
Y3
X4
X3
X2
X1
X2M
29
28
21
4
X1Y
1 2
4
29
28
21
X2M
13a
A3P
2
1
N
L
A2P
P2
P1
X5M
2
1
A2P
2
1
10
9
8
7
4
X5M
3
4
3
2
1
DS1
5
4
3
X801M
2
1
A8P
X5M
6
5
SS1
A4P
P2
P1
Switch box
Power limitation digital
inputs: 12 V DC / 12 mA
detection
(voltage supplied by PCB)
only for domestic
hot water option
Only for demand PCB option
Demand PCB
OFF
ON
ext. ambient
sensor option
(indoor or outdoor)
only for floor
standing model
Switch
box
Switch
box
Preferential kWh rate
power supply contact:
16 V DC detection
(voltage supplied by
PCB)
Electric pulse meter
inputs: 5 V DC pulse
detection (voltage
supplied by PCB)
Digital I/O PCB
Alarm output
Max. load
0.3 A - 250 V AC
Min. load
20 mA - 5 V DC
Solar pump connection
For *KSOLHWAV1, refer to
operation manual
Min. load 20 mA - 5 V DC
Max. load 0.3 A - 250 V AC
Ext. heat source
Remote user
interface
User interface
OFF
ON
Only for digital I/O PCB option
Options: bottom plate heater OR On/OFF output
Options: boiler output, solar pump connection, alarm output
only if no EKBPHT*
Min. load 20 mA - 5 V DC
Max. load 0.3 A - 250 V AC
On/OFF output
Space C/H
to bottom
plate heater
only for EKBPHT*
only for solar pump station
OUTDOOR
UNIT