Installer reference guide
45
08 + ERLQ004~008
Daikin Altherma - Low Temperature Split
4P313774-1 – 2012.05
8 Configuration
8.2.3 Quick wizard: Options
Domestic hot water settings
This chapter only applies to systems with a domestic hot water tank
installed:
Q
EHBH/X: an optional domestic hot water tank is available,
Q
EHVH/X: a domestic hot water tank is standard incorporated into
the indoor unit.
Following settings must be made accordingly.
Thermostats and external sensors
See "5 Application guidelines" on page 9.
[A.2.1.9]
[F-0D]
When the space heating/cooling control
is OFF by the user interface, the pump is
always OFF. When the space
heating/cooling control is On, you can
select the desired pump operation mode
(only applicable during space
heating/cooling)
Pump operation mode:
Q
0 (Continuous): Continuous pump
operation, regardless of thermo ON
or OFF condition. Remark:
continuous pump operation requires
more energy than sample or request
pump operation.
Q
1 (Sample)(default): The pump is
ON. When there is heating or
cooling demand as the the leaving
temperature has not reached the
desired temperature yet. When
thermo OFF condition occurs, the
pump runs every 5 minutes to check
the water temperature and demand
heating or cooling if necessary.
Remark: Sample is NOT available in
extended room thermostat control or
room thermostat control.
Q
2 (Request): Pump operation based
on request. Example: Using a room
thermostat creates thermo ON/OFF
condition. When there is no such
demand, the pump is OFF. Remark:
Request is NOT available in leaving
water temperature control.
#
Code
Description
#
Code
Description
[A.2.2.1]
[E-05]
DHW operation:
Q
0 (No): NOT installed. Default for
EHBH/X.
Q
1 (Yes): Installed. Default for
EHVH/X. Remark: For EHVH/X, the
domestic hot water tank is by default
installed. Do NOT change this
setting.
[A.2.2.3]
[E-07]
During domestic hot water preparation,
the heat pump can be assisted by an
electrical heater to ensure the domestic
hot water preparation even for high
desired tank temperatures.
DHW tank heater:
Q
0 (Horizontal BSH): Installed at side
of the tank. Default for EHBH/X.
Q
1 (Backup heater): Default for
EHVH/X. The backup heater will
also be used in domestic hot water
heating.
[A.2.2.A]
[D-02]
The indoor unit offers the possibility to
connect a field supplied domestic hot
water pump (On/OFF type). Depending
on the installation and configuration on
the user interface, we distinguish its
functionality.
DHW pump:
Q
0 (No)(default): NOT installed.
Q
1 (Secondary rtrn): Installed for
instant hot water when water is
tapped. The end-user sets the
operation timing (weekly schedule
time) of the domestic hot water
pump when it should run. Control of
this pump is possible through the
indoor unit.
Q
2 (Disinf. shunt): Installed for
disinfection. It runs when the
disinfection function of the domestic
hot water tank is running. No further
settings are needed.
See also illustrations below.
Domestic hot water pump installed for…
Instant hot water
Disinfection
a
Indoor unit
b
Tank
c
Domestic hot water pump
d
Heater element
e
Non-return valve
f
Shower
g
Cold water
c
f
b
a
g
c
b
a
d
f
e
g