08 + ERLQ004~008
Daikin Altherma - Low Temperature Split
4P313774-1 – 2012.05
Installer reference guide
6
4 About the units and options
3.2.2 To remove the accessories from the indoor
unit
The installation manual indoor unit, operation manual, and CD are
located in the upper part of the box. Follow the procedure below to
remove the other accessories.
1
Remove the screws at the bottom of the unit.
2
Tilt the bottom side of the front panel upwards and remove it.
3
Remove the accessories.
4
About the units and options
4.1
Identification
4.1.1 Identification label: Outdoor unit
Location
Model identification
Example: ER L Q 006 CA V3
4.1.2 Identification label: Indoor unit
Location
a
General safety precautions
b
Addendum book for optional equipment
c
Indoor unit installation manual
d
Operation manual
e
CD
f
User interface kit: user interface, 4 fixing screws, 2 plugs
g
Shut-off valve
h
User interface cover
i
Hinges for user interface cover
2x
f+g
d
e
i
a
1x
b
1x
c
1x
d
1x
g
2x
h
1x
2x
f
1x
e
1x
NOTICE
When installing or servicing several units at the same time,
make sure NOT to switch the service panels between
different models.
Code
Explanation
ER
European split outdoor pair heat pump
L
Low water temperature – ambient zone:
L=–10~–20°C
Q
Refrigerant R410A
006
Capacity class:
Q
004=4.5 kW
Q
006=6 kW
Q
008=7.5 kW
CA
Series
V3
V3=1~, 230 V, 50 Hz