Q
If you install the unit on a frame, install a waterproof plate within
150 mm of the underside of the unit in order to prevent the
invasion of water in the unit and to avoid the drain water dripping
(see the following illustration).
An additional drain pan kit (EKDP008CA) can be used to gather the
drain water. The drain pan kit consists of:
7.2.4 To prevent the outdoor unit from falling over
In case the unit is installed in places where strong wind can tilt the
unit, take following measure:
1
Prepare 2 cables as indicated in the following illustration (field
supply).
2
Place the 2 cables over the outdoor unit.
3
Insert a rubber sheet between the cables and the outdoor unit to
prevent the cable from scratching the paint (field supply).
4
Attach the cable’s ends. Tighten those ends.
7.3
Mounting the indoor unit
7.3.1 To install the indoor unit
NOTICE
If the drain holes of the outdoor unit are blocked up, provide
space of at least 300 mm below the outdoor unit.
a
Drain pan
b
U-beams
a
b
283 mm
580 mm
CAUTION
Do NOT grasp the piping to lift the indoor unit.
2x
2x
60kg
1
2
4
3