Installer reference guide
43
08 + ERLQ004~008
Daikin Altherma - Low Temperature Split
4P313774-1 – 2012.05
8 Configuration
8.1.4 To copy the language set from the first to the
second user interface
See "8.1.3 To copy the system settings from the first to the second
user interface" on page 42.
8.1.5 Quick wizard: Set the system layout after
first power ON
After first power ON of the system, you are guided on the user
interface to do initial settings:
Q
language,
Q
date,
Q
time,
Q
system layout.
By confirming the system layout, you can proceed with the
installation and commissioning of the system.
1
At power ON, the quick wizard starts as long as the system
layout was NOT confirmed yet, by setting the language.
2
Set the current date and time.
3
Set the system layout settings: Standard, Options, Capacities.
For more details, see Basic configuration.
4
Confirm by pressing
.
5
The user interface re-initialises and you can proceed the
installation by setting the other applicable settings and
commissioning of the system.
When the installer settings are changed, the system will request to
confirm. When confirmation is complete, the screen will shortly turn
OFF and "busy" will be displayed for several seconds.
8.2
Basic configuration
8.2.1 Quick wizard: Language / time and date
8.2.2 Quick wizard: Standard
Backup heater configuration (only for *9W model)
The backup heater in a *9W model is adapted to be connected to
most common European electricity grids. Besides hardware
configuration, the backup heater type must be set on the user
interface.
Space heating/cooling settings
The system can heat up or cool down a space. Depending on the
type of application, the space heating/cooling settings must be made
accordingly.
#
Code
Description
[A.1]
N/A
Language
[1]
N/A
Time and date
#
Code
Description
[A.2.1.5]
[5-0D]
BUH type:
Q
1 (1P,(1/1+2)): 3 kW 1~ 230 V (*9W)
Q
3 (3P,(1/1+2)): 6 kW 3~ 230 V (*9W)
Q
4 (3PN,(1/2)): 6 kW 3N~ 400 V
(*9W)
Q
5 (3PN,(1/1+2)): 9 kW 3N~ 400 V
(*9W)
#
Code
Description
[A.2.1.7]
[C-07]
Unit control method:
Q
0 (LWT control): Unit operation is
decided based on the leaving water
temperature regardless the actual
room temperature and/or heating or
cooling demand of the room.
Q
1 (Ext RT control): Unit operation is
decided by the external thermostat
or equivalent (e.g. heat pump
convector).
Q
2 (RT control): Unit operation is
decided based on the ambient
temperature of the user interface.