Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

DBG180*/ DBG240*          208-230/ 3 / 60  

  

2 SPEED

WIRING DIAGRAMS

2

1

    W1 TO W2 WIRE JUMPER.

5. FOR TWO STAGE OPERATION REMOVE

FALSE FLAME SENSED

OPEN LIMIT SWITCH

WITHOUT INDUCER ON

PRESSURE SWITCH CLOSED

OPEN

PRESSURE SWITCH

NORMAL OPERATION

3 BLINKS

6 BLINKS

4 BLINKS

5 BLINKS

OUTPUT DELAY

COMPRESSOR

OFF

ON

1 BLINK

2 BLINKS

STATUS LIGHT

SWITCH

OPEN AUX. LIMIT

IGNITION FAILURE

SWITCH

OPEN ROLLOUT

INTERNAL CONTROL

NO POWER OR

EQUIPMENT STATUS

PRESSURE SWITCH

CHECK

BAD SWITCH

MAIN LIMIT OPEN

STICKING GAS VALVE

ANTI-CYCLE TIMER

3 MIN. COMP.

PRESSURE SWITCH

CHECK

GAS PRESSURE

FLAME ROLLOUT

AUX. LIMIT OPEN

FLAME SENSOR

BAD SWITCH

GAS VALVE

GAS FLOW

REPLACE CONTROL

CHECK FUSE ON CONTROL

CHECK INPUT POWER

------

CHECK

HPS2

LPS2

IIC

9

11

12

8

6

3

ECON

10

PS

ALS

L1

4

5

F

RS

L2

5

4

7

8

6

9

1

2

3

TR

24V

SUPPLY VOLTAGE

208-240/3/60

L2

1

3

1

3

CC1

T3

COMP1

T2

F

CM1

T1

C

T2

VM

VENT MOTOR RELAY

VENT MOTOR

TRANSFORMER

TERMINAL BLOCK (24V SIGNAL)

ROLLOUT SWITCH

PRESSURE SWITCH

FEMALE PLUG/CONNECTOR

LIMIT SWITCH

LOW PRESSURE SWITCH

IGNITOR

INTEGRATED IGNITION CONTROL

INDOOR BLOWER RELAY

HIGH PRESSURE SWITCH

GAS VALVE

EQUIPMENT GROUND

FLAME SENSOR

FAN CAPACITOR

FUSE

EVAPORATOR MOTOR

COMPRESSOR CONTACTOR

CONDENSER MOTOR

COMPRESSOR

BLOWER CONTACTOR

AUXILLARY LIMIT SWITCH

VM

TR

TB1

RS

PS

PLF

LS

LPS

IGN

IIC

IBR

HPS

GV

GND

FS

FC

F

EM

CC

CM

COMP

BC

ALS

NOTES

2

(USE COPPER CONDUCTOR ONLY).

SIZE AND TYPE OF INSULATION AS ORIGINAL.

1. REPLACEMENT WIRE MUST BE THE SAME

3

ACCESSORY.

ATTACH FEMALE PLUG TO THE ECONOMIZER

COMPARTMENT. REMOVE MALE PLUG AND

TO BLOWER HOUSING IN RETURN AIR

2. ACCESSORY ECONOMIZER PLUG ADJACENT

4. USE COPPER CONDUCTORS ONLY.

USE NEC CLASS 2 WIRE.

4

3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.

0140L03767-A

COMPONENT LEGEND

T1

TERMINAL BLOCK (L1)

TB2

2

FROM TERMINAL 3 TO TERMINAL 2 ON THE TRANSFORMER.

6. FOR 208V OPERATION MOVE BLACK WIRE

OF OVER CURRENT PROTECTION

SEE UNIT RATING PLATE FOR TYPE AND SIZE

PB

POWER DISTRUBTION BLOCK

CRANK CASE HEATER

CCH

CRANK CASE HEATER RELAY

CCHR

2

1

1

CCH1

CCH2

C

CM2

F

FC2

CCR

COMPRESSOR CONTACTOR RELAY

T2

CC2

T1

CC2

T2

COMP2

T3

CC2

FACTORY WIRING

THERMOSTAT

FIELD WIRING

HIGH VOLTAGE

LOW VOLTAGE

FIELD WIRING

LINE VOLTAGE

LOW VOLTAGE

HIGH VOLTAGE

WIRE CODE

BK

BLACK

BL

BLUE

BR

BROWN

GR

GREEN

OR

ORANGE

PK

PINK

PU

PURPLE

RD

RED

WH

WHITE

YL

YELLOW

YL/PK YELLOW WITH

PINK STRIP

BL/PK BLUE WITH

PINK STRIP

Y1

TB1

W

G

W

PK

RD

Y1

R

OR

BL

GR

C

2 STAGE COOLING

WH

O

STAT

O

Y2

C

G

R

YL

W1 TO W2 WIRE JUMPER.

5. FOR TWO STAGE OPERATION REMOVE

INSTALLER/SERVICEMAN

TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:

THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO

CCR2

7

NOTE 3

FS

GV

CCR1

IGN

FS

TB1

L1

L3

FC1

F

CC1

C

CC1

NOTES

2

(USE COPPER CONDUCTOR ONLY).

SIZE AND TYPE OF INSULATION AS ORIGINAL.

1. REPLACEMENT WIRE MUST BE THE SAME

3

ACCESSORY.

ATTACH FEMALE PLUG TO THE ECONOMIZER

COMPARTMENT. REMOVE MALE PLUG AND

TO BLOWER HOUSING IN RETURN AIR

2. ACCESSORY ECONOMIZER PLUG ADJACENT

4. USE COPPER CONDUCTORS ONLY.

USE NEC CLASS 2 WIRE.

4

3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.

T3

208-240v

FROM TERMINAL 3 TO TERMINAL 2 ON THE TRANSFORMER.

6. FOR 208V OPERATION MOVE BLACK WIRE

2

CCHR2

6

4

SEE NOTE 7

T3

T1

Y1

TB1

W

G

PK

RD

OR

BL

GR

WH

O

STAT

Y2

C

R

YL

C

H

2

4

2

4

HPS1

LPS1

D1

VMR

4

6

CC1

CC2

CCR2

CCR1

FC3

F

CM3

C

R

C

WH

G

O

W1

Y2

S1

RD

S2

W2

Y1

NOTE 5

LS

Y2

TO THERMOSTAT

OPTIONAL

VMR

BLOWER RELAY

BR

CCHR1

CCHR2

CIRCUIT BREAKER

CB

EM

HIGH SPEED

LOW SPEED

BC2

CB2

CB1

BC1

CB2

BC2

BC2

CB2

BC1

CB1

BC1

CB1

BC1

BC2

2

5

4

BR1

BR1

BR2

2

5

4

BR2

VMR

1

3

1

3

1

3

1

3

SEE

NOTE 2

CCHR1

6

4

Summary of Contents for DBG Series

Page 1: ...ndex Replacement Parts 2 Safety Instructions 2 General Information 3 Unit Location 4 Clearances 6 Roof Curb Post Installation Checks 6 Roof Top Duct Connections 6 Rigging Details 6 Electrical Wiring 8...

Page 2: ...ATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF TURN OFF THE MANUAL GAS SHUTOFF VALVE EXTERNAL TO THE FURNACE BEFORE TURNING OFF THE ELECTRICAL SUPPLY WARNING SHEET METAL PARTS SCREWS CLIPS AND SIMILAR...

Page 3: ...National Codes It is the installer s responsibility to install the product in accordance with National Codes and or prevailing local codes and regulations The heating and cooling capacities of the un...

Page 4: ...t in an area where the outdoor air i e combustionairfortheunit willbefrequentlycontaminated by compounds containing chlorine or fluorine Common sources of such compounds include swimming pool chemical...

Page 5: ...ove wooden struts and shipping brace per installation instructions The struts are located in the fork holes and are used to protect the unit from damage while lifting with forks The shipping brace is...

Page 6: ...ance around the unit should be kept for safety service maintenance and proper unit operation A clearance of 75 on the service side of the unit is recommended to facilitate possible blower assembly sha...

Page 7: ...contact with the unit during transport Remove wood strutsmountedbeneathunitbaseframebeforesettingunit on roof curb These struts are intended to protect unit baseframefromforkliftdamage Removalisaccomp...

Page 8: ...HE WIRING PROTECT WIRING FROM SHARP EDGES FOLLOW NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES AND ORDINANCES DO NOT ROUTE WIRES THROUGH REMOVABLE ACCESS PANELS CAUTION CONDUIT AND FITTINGS MUST BE WEA...

Page 9: ...AND LOW VOLTAGE BLOCK LOCATIONS R control wiring through grommet control wiring Field for linev oltage Ground Lug Field wiring enters from LOW HIGH 25 TONS MODEL POWER AND LOW VOLTAGE BLOCK LOCATIONS...

Page 10: ...RNING IMPORTANT NOTE This unit is factory set to operate on natural gas at the altitudes shown on the rating plate TO PREVENT PROPERTY DAMAGE PERSONAL INJURY OR DEATH WHEN EITHER USING PROPANE GAS ALO...

Page 11: ...to the gas valve to keep it from turning 6 Install a manual shut off valve in a convenient location within six feet of unit between the meter and the unit 7 Tighten all joints securely 8 The unit must...

Page 12: ...high fire and within 6 7 7 3 inches w c low fire at the manifold with all gas appliances in operation Maintaining proper gas pressure depends on three main factors 1 Vaporization rate which depends on...

Page 13: ...3 8 W C WARNING THIS UNIT MUST BE ISOLATED FROM THE GAS SUPPLY PIPING SYSTEM BY CLOSING ITS INDIVIDUAL MANUAL SHUTOFF VALVE DURING ANY PRESSURE TESTING EQUAL TO OR LESS THAN 1 2 PSIG CAUTION 7 There m...

Page 14: ...Responsibility The installing contractor must be certain that All supply and return air ductwork is in place properly sealed and corresponds with installation instructions All thermostats are mounted...

Page 15: ...or nameplate amps are not exceeded A final check of amp draw should be made upon completion of air balancing of the duct system see Appendix B Set Evaporator Fan Rpm Actual RPM s must be set and verif...

Page 16: ...n device which automatically lights the main burner DO NOT try to light burner by any other method 6 Move the gas control valve switch to the OFF position Do not force 7 Wait five minutes to clear out...

Page 17: ...he dripleg and installing a predrilled cap with a hose fitting With Power And Gas On 2 Put unit into heating cycle and turn on all other gas consuming appliances NATURAL Min 5 0 W C Max 10 0 W C PROPA...

Page 18: ...Using a leak detection solution or soap suds check for leaks at pressure boss screw Bubbles forming indicate a leak SHUT OFF GAS AND FIX ALL LEAKS IMMEDIATELY TO PREVENT UNRELIABLE OPERATION OR EQUIPM...

Page 19: ...lose manual gas shut off valve external to the unit 6 Replace the heat exchanger door on the unit 7 If cooling and or air circulation will be desired turn ON the electrical power Automatic Reset High...

Page 20: ...igeration Sequence Check With the disconnect switch open remove the field connected ther mostat wire from terminal R on TB1 terminal block Place a jumper across terminals R and G and across R and Y on...

Page 21: ...e maintenance is the best way to avoid unnecessary expense and inconvenience Have this system inspected at regu lar intervals by qualified service personnel at least twice a year Routine maintenance s...

Page 22: ...Y ADJUSTMENT CONTACT A QUALIFIED SERVICER AT ONCE IF AN ABNORMAL FLAME SHOULD DEVELOP WARNING At least once a year prior to or during the heating season make a visual check of the burner flames NOTE T...

Page 23: ...ains on The diagnostic fault code is two flashes Pressure Switch Stuck Closed 3 FLASH CODE A stuck closed pressure switch can be caused by a faulty pressure switch or faulty wiring If the control enco...

Page 24: ...BHP 0 2 9359 4 92 8991 3 79 8621 3 54 8188 3 27 7826 3 04 0 4 9018 3 18 8632 4 39 8251 3 39 7867 3 15 7363 2 85 6992 2 63 0 6 8279 2 96 7879 3 86 7484 2 99 7085 2 75 0 8 7957 4 82 7513 2 73 7097 3 35...

Page 25: ...6 8250 6 12 7657 5 40 7033 4 74 1 2 8934 7 89 8550 7 25 8175 6 57 7598 5 72 7043 5 04 6394 4 38 1 4 8424 7 49 8071 6 91 7639 6 21 7041 5 38 6318 4 63 1 6 7959 7 21 7609 6 57 7088 5 84 6295 4 97 1 8 74...

Page 26: ...RE DROP SCFM 4500 5000 5500 6000 6500 7000 7500 8000 8500 9000 9500 10000 In WG 0 15 0 18 0 22 0 27 0 32 0 37 0 42 0 48 0 55 0 61 0 69 0 76 Airflow Pressure Drop of Downflow Economizer for 15 to 25 To...

Page 27: ...lt Drive 7 50 7 5 DCG1807V 575 3 60 9 0 78 0 9 0 78 0 3 0 33 0 7 Model Number Electrical Rating Compressor Circuit 1 Compressor Circuit 2 Outdoor Fan Motor Indoor Fan Motor Optional Powered Convienien...

Page 28: ...DIMENSIONS VERTICAL DISCHARGE TOP VIEW 21 60 7 48 22 B C D A Model A B C D 15 Ton 20 Ton 133 1 2 88 7 32 50 9 32 5 5 32 25 Ton 133 1 2 88 7 32 53 9 32 5 5 32 NOTE 15 20 ton models have 3 fans 25 ton...

Page 29: ...29 APPENDIX D WIRING DIAGRAMS...

Page 30: ...ED CB2 L2 T3 L1 T2 L3 T1 HIGH SPEED CB1 L2 T3 L1 T2 L3 T1 OR RD BK GY BL YL YL BL GY BK RD OR L3 T3 L2 CC1 L1 T1 T2 L3 T3 L2 CC2 L1 T1 T2 L3 T3 L2 BC1 L1 T1 T2 L3 T3 L2 BC2 L1 T1 T2 T3 T2 T1 COMP 1 RD...

Page 31: ...S ONLY USE NEC CLASS 2 WIRE 4 3 L1 AND L2 ON IIC CONTROL IS 24V INPUT 0140L03767 A COMPONENT LEGEND T1 TERMINAL BLOCK L1 TB2 2 FROM TERMINAL 3 TO TERMINAL 2 ON THE TRANSFORMER 6 FOR 208V OPERATION MOV...

Page 32: ...L3 T1 HIGH SPEED CB1 L2 T3 L1 T2 L3 T1 OR RD BK GY BL YL YL BL GY BK RD OR L3 T3 L2 CC1 L1 T1 T2 L3 T3 L2 CC2 L1 T1 T2 L3 T3 L2 BC1 L1 T1 T2 L3 T3 L2 BC2 L1 T1 T2 T3 T2 T1 COMP 1 RD YL BK CCH1 T3 T2...

Page 33: ...33 Wiring is subject to change Always refer to the wiring diagram on the unit for the most up to date wiring DBG180 DBG240 460 575 3 60 2 SPEED WIRING DIAGRAMS...

Page 34: ...RE SWITCH MAIN LIMIT OPEN BAD SWITCH STICKING GAS VALVE 3 MIN COMP ANTI CYCLE TIMER L2 L3 L1 L2 L3 L1 IIC DIAGNOSTIC BLINK CODES L1 L2 L3 LINE VOLTAGE YL RD BK PU OR 7 7 SEE ACCESSORY KIT LITERATURE F...

Page 35: ...FOR OPTIONAL CONVENIENCE OUTLET WIRING DIAGRAM POWER DIAGRAM F L P M L P PLM PLF BK RD PU L1 L2 L3 T1 T2 T3 LAC MC YL BK BR BK BR YL T3 T2 T1 BR L1 L2 L3 T1 T2 T3 EM GY BL YL RD BL BK OR RD YL BK OR...

Page 36: ...VOLTAGE TERMINAL BLOCK 4 TERMINALS FOR 24VAC PWR RD BK BR WIRE AND 6 TERMINALS FOR 24VAC COM BL WIRE 4 CONNECTIONS SHOWN ARE FOR 1 STAGE HEAT OPERATION WHEN 2 STAGE OPERATION IS REQUIRED REMOVE WH JU...

Page 37: ...necessary Check unit wiring to ensure it is not in contact with refrigerant piping or sharp metal edges Tighten as needed Verify that the crankcase heaters have been energized for 24 hours 9 2014 Date...

Page 38: ...2 Compressor Amps Blower Amps Condenser Fan Amps ELECTRICAL Total External Static Pressure Blower Wheel RPM TEMPERATURES Outdoor Air Temperature Return Air Temperature Cooling Supply Air Temperature...

Page 39: ...39 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 40: ...products may mean a change in specifications without notice 2019 CUSTOMER FEEDBACK Daikin is very interested in all product comments Please fill out the feedback form on the following link https daiki...

Reviews: