background image

6 Maintenance and service

Operation manual

16

(C)(F)TXA15~50A2V1B(W)(S)(T)

Daikin room air conditioner

3P485919-7C – 2017.12

1

2

3

Remove the titanium apatite deodorizing filter and silver particle
filter from the tabs.

4

Wash  the  air  filters  with  water  or  clean  them  with  a  vacuum
cleaner.

5

Soak in lukewarm water for about 10 to 15 minutes.

INFORMATION

▪ If the dust does NOT come off easily, wash them with a

neutral detergent diluted in lukewarm water. Dry the air
filters in the shade.

▪ It  is  recommended  to  clean  the  air  filters  every  2

weeks.

6.7

To clean the titanium apatite
deodorizing filter and the silver
particle filter (Ag-ion filter)

INFORMATION

▪ Replace the filter every 3 years.

▪ Clean the filter with water every 6 months.

1

Remove the dust from the filter with a vacuum cleaner.

2

Soak  the  filter  for  10  to  15  minutes  in  warm  water.  Do  NOT
remove the filter from frame.

3

After washing, shake off remaining water and dry the filter in the
shade. Do NOT wring out the filter when removing water.

6.8

To replace the titanium apatite
deodorizing filter and the silver
particle filter (Ag-ion filter)

1

Remove the tabs on the filter frame and replace the filter with a
new one.

INFORMATION

▪ Do NOT throw away the filter frame, but use it again.

▪ Dispose of the old filter as non-flammable waste.

6.9

To close the front panel

1

Set the filters as they were.

2

Lift  the  front  panel  slightly  and  remove  the  support  from  the
fixing tab.

a

b

c

a

Backside of the front panel

b

Fixing tab

c

Support

3

Close the front panel.

4

Gently press the front panel down until it clicks.

6.10

To remove the front panel

INFORMATION

Remove the front panel only in case it MUST be replaced.

1

Open  the  front  panel.  See 

"6.4  To  open  the  front  panel"  on

page 15

.

2

Open  the  panel  locks  located  on  the  back  side  of  the  panel
(1 on each side).

a

a

Summary of Contents for CTXA15A2V1BW

Page 1: ...ual Daikin room air conditioner CTXA15A2V1BW FTXA20A2V1BW FTXA25A2V1BW FTXA35A2V1BW FTXA42A2V1BW FTXA50A2V1BW CTXA15A2V1BS FTXA20A2V1BS FTXA25A2V1BS FTXA35A2V1BS FTXA42A2V1BS FTXA50A2V1BS CTXA15A2V1BT...

Page 2: ...Ag ion filter 16 6 8 To replace the titanium apatite deodorizing filter and the silver particle filter Ag ion filter 16 6 9 To close the front panel 16 6 10 To remove the front panel 16 6 11 To take f...

Page 3: ...rticle filter is interchangeable ON OFF button If the user interface is missing you can use the ON OFF button on the indoor unit to start stop operation When operation is started using this button the...

Page 4: ...Weekly timer is active Day of the week Icon Description Current time 2 2 3 To operate the user interface a 500 mm a Signal receiver Note Make sure that there are no obstacles within 500 mm under the s...

Page 5: ...rightness of the indoor unit display Adjust the brightness of the indoor unit display as desired or turn OFF the display 3 4 1 To set the brightness of the indoor unit display 1 Press for at least 2 s...

Page 6: ...Streamer To remove airborne allergens such as mold pollen adjuvant substances viruses bacteria Econo To use the system when you are also using other power consuming appliances To save energy Outdoor...

Page 7: ...adjust the airflow rate 1 Press to change the airflow setting as follows 4 3 3 Airflow direction When Adjust the airflow direction as desired What The system directs the airflow differently depending...

Page 8: ...elected Comfort airflow operation will be cancelled To turn ON OFF Vertical airflow function 1 Press for at least 2 seconds Result The menu appears on the display 2 Press or to change the menu screen...

Page 9: ...ady low Econo operation will NOT further reduce power consumption Outdoor unit quiet operation Use Outdoor unit quiet operation when you want to decrease the noise level of the outdoor unit Example At...

Page 10: ...t time are displayed on the LCD The timer lamp lights up INFORMATION Each time or is pressed the time setting advances by 10 minutes Holding the button down will change the setting rapidly 4 To stop o...

Page 11: ...ture Note The set temperature is only displayed when the mode setting is on 9 Press Result Temperature and time are set in ON timer Time is set in OFF timer Timer lamp lights orange Result New reserva...

Page 12: ...Smartphone tablet or another smart device with one of the following operating systems Android 4 0 3 or later iOS 7 1 2 or later Internet line and communication device such as a modem router etc Wirele...

Page 13: ...onds in the default screen Result The confirmation display menu appears 2 Keep pressing or until the AP setting display menu appears 3 Press to confirm the selection Result is blinking 4 Connect with...

Page 14: ...the air outlet of the unit Doing so may cause a reduced heating cooling effect or stop operation Turn off the main power supply switch to the unit when the unit is NOT used for longer periods of time...

Page 15: ...C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brush Possible consequence The surface finishing peels off DANGER RISK OF ELECTROCU...

Page 16: ...or 10 to 15 minutes in warm water Do NOT remove the filter from frame 3 After washing shake off remaining water and dry the filter in the shade Do NOT wring out the filter when removing water 6 8 To r...

Page 17: ...main power switch If water leaks from the unit Stop the operation The operation switch does NOT work well Turn OFF the power supply If the user interface display indicates the unit number the operatio...

Page 18: ...o insert the batteries on page 4 Make sure that the transmitter is NOT exposed to direct sunlight Check if there are any electronic starter type fluorescent lamps in the room Contact your dealer The u...

Page 19: ...utdoor unit Indoor outdoor unit combination fault Indoor unit Error code Description Indoor unit PCB abnormality Freeze up protection or high pressure control Fan motor DC motor abnormality Streamer u...

Page 20: ...channel MUST be between 1 11 Check if communication is OK See To confirm the wireless adapter connection status on page 12 Try to resetting to the factory default and repeat the setting See To reset t...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...3P485919 7C 2017 12 Copyright 2017 Daikin...