background image

4 Operation

Operation manual

10

(C)(F)TXA15~50A2V1B(W)(S)(T)

Daikin room air conditioner

3P485919-7C – 2017.12

INFORMATION

Program the timer again in case of:

▪ A breaker has turned the unit off.

▪ A power failure.

▪ After replacing batteries in the user interface.

INFORMATION

The  clock  MUST  be  set  correctly  before  using  any  timer
functions. Refer to 

"3.3.1 To set the clock" on page 5

.

4.5.1

To start/stop OFF timer operation

1

Press 

 to start.

Result: 

 is displayed on the LCD, the timer lamp lights

up,  and 

  blinks.    and  the  day  of  the  week  disappear  from

the LCD.

2

Press 

 or 

 to change the time setting.

3

Press 

 again.

Result: 

 and the set time are displayed on the LCD.

Result: 

The timer lamp lights up.

INFORMATION

Each  time 

  or 

  is  pressed,  the  time  setting

advances  by  10  minutes.  Holding  the  button  down  will
change the setting rapidly.

4

To stop operation, press 

.

Result: 

  and 

  disappear  from  the  LCD  and  the  timer

lamp goes off.   and the day of the week are displayed on the LCD.

INFORMATION

When you set the ON/OFF timer, the time setting is stored
in  the  memory.  The  memory  will  be  reset  when  the  user
interface batteries are replaced.

Use of night set mode in combination with OFF timer

The  air  conditioner  automatically  adjusts  the  temperature
setting  (0.5°C  up  in  cooling,  2.0°C  down  in  heating)  to
prevent 

excessive 

cooling/heating 

and 

ensure 

a

comfortable sleeping temperature.

4.5.2

To start/stop ON timer operation

1

Press 

 to start.

Result: 

 is displayed on the LCD, the timer lamp lights

up,  and 

  blinks.    and  the  day  of  the  week  disappear  from

the LCD.

2

Press 

 or 

 to change the time setting.

3

Press 

 again.

Result: 

  and  the  set  time  are  displayed  on  the  LCD.  The  timer

lamp lights up.

INFORMATION

Each  time 

  or 

  is  pressed,  the  time  setting

advances  by  10  minutes.  Holding  the  button  down  will
change the setting rapidly.

4

To stop operation, press 

.

Result: 

 and 

 disappear from the LCD and the timer

lamp goes off.   and the day of the week are displayed on the
LCD.

4.5.3

To combine OFF timer and ON timer

1

To  set  the  timers,  refer  to 

"4.5.1  To  start/stop  OFF  timer

operation"  on  page  10

  and 

"4.5.2  To  start/stop  ON  timer

operation" on page 10

.

Result: 

 and 

 are displayed on the LCD.

Example:

Display

Current time

Set while…

Operation

6:00

the unit is
operating.

Stops at 7:00
and starts at
14:00.

the unit is NOT
operating.

Starts at 14:00.

Note: 

 If the timer setting is active, the current time is NOT displayed

on the LCD.

4.6

Weekly timer operation

With this operation, you can save up to 4 timer settings for each day
of the week.

Example: 

  Create  a  different  setting  from  Monday  to  Friday  and  a

different setting for weekends.

Day of the week

Setting example

Monday

▪ Make up to 4 settings.

6:00

8:30

17:30

25°C

27°C

22:00

1

2

3

4

ON

OFF

ON

OFF

Tuesday~Friday

▪ Use the copy mode if the

settings are the same as
for Monday.

6:00

8:30

17:30

25°C

27°C

22:00

1

2

3

4

ON

OFF

ON

OFF

Saturday

▪ No timer setting

Sunday

▪ Make up to 4 settings.

8:00 10:00

19:00 21:00

27°C

27°C

25°C

ON

OFF

OFF

ON

1

2

3

4

ON-ON-ON-ON  setting.

  Enables  scheduling  the  operation  mode

and set temperature.

OFF-OFF-OFF-OFF setting.

 Only the turn off time can be set for

each day.

Note: 

 Be sure to aim the user interface at the indoor unit and check

for  a  receiving  tone  when  setting  the  Weekly  timer  operation.  See

"2.2.3 To operate the user interface" on page 4

.

INFORMATION

The  clock  MUST  be  set  correctly  before  using  any  timer
functions. Refer to 

"3.3.1 To set the clock" on page 5

.

Summary of Contents for CTXA15A2V1BW

Page 1: ...ual Daikin room air conditioner CTXA15A2V1BW FTXA20A2V1BW FTXA25A2V1BW FTXA35A2V1BW FTXA42A2V1BW FTXA50A2V1BW CTXA15A2V1BS FTXA20A2V1BS FTXA25A2V1BS FTXA35A2V1BS FTXA42A2V1BS FTXA50A2V1BS CTXA15A2V1BT...

Page 2: ...Ag ion filter 16 6 8 To replace the titanium apatite deodorizing filter and the silver particle filter Ag ion filter 16 6 9 To close the front panel 16 6 10 To remove the front panel 16 6 11 To take f...

Page 3: ...rticle filter is interchangeable ON OFF button If the user interface is missing you can use the ON OFF button on the indoor unit to start stop operation When operation is started using this button the...

Page 4: ...Weekly timer is active Day of the week Icon Description Current time 2 2 3 To operate the user interface a 500 mm a Signal receiver Note Make sure that there are no obstacles within 500 mm under the s...

Page 5: ...rightness of the indoor unit display Adjust the brightness of the indoor unit display as desired or turn OFF the display 3 4 1 To set the brightness of the indoor unit display 1 Press for at least 2 s...

Page 6: ...Streamer To remove airborne allergens such as mold pollen adjuvant substances viruses bacteria Econo To use the system when you are also using other power consuming appliances To save energy Outdoor...

Page 7: ...adjust the airflow rate 1 Press to change the airflow setting as follows 4 3 3 Airflow direction When Adjust the airflow direction as desired What The system directs the airflow differently depending...

Page 8: ...elected Comfort airflow operation will be cancelled To turn ON OFF Vertical airflow function 1 Press for at least 2 seconds Result The menu appears on the display 2 Press or to change the menu screen...

Page 9: ...ady low Econo operation will NOT further reduce power consumption Outdoor unit quiet operation Use Outdoor unit quiet operation when you want to decrease the noise level of the outdoor unit Example At...

Page 10: ...t time are displayed on the LCD The timer lamp lights up INFORMATION Each time or is pressed the time setting advances by 10 minutes Holding the button down will change the setting rapidly 4 To stop o...

Page 11: ...ture Note The set temperature is only displayed when the mode setting is on 9 Press Result Temperature and time are set in ON timer Time is set in OFF timer Timer lamp lights orange Result New reserva...

Page 12: ...Smartphone tablet or another smart device with one of the following operating systems Android 4 0 3 or later iOS 7 1 2 or later Internet line and communication device such as a modem router etc Wirele...

Page 13: ...onds in the default screen Result The confirmation display menu appears 2 Keep pressing or until the AP setting display menu appears 3 Press to confirm the selection Result is blinking 4 Connect with...

Page 14: ...the air outlet of the unit Doing so may cause a reduced heating cooling effect or stop operation Turn off the main power supply switch to the unit when the unit is NOT used for longer periods of time...

Page 15: ...C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brush Possible consequence The surface finishing peels off DANGER RISK OF ELECTROCU...

Page 16: ...or 10 to 15 minutes in warm water Do NOT remove the filter from frame 3 After washing shake off remaining water and dry the filter in the shade Do NOT wring out the filter when removing water 6 8 To r...

Page 17: ...main power switch If water leaks from the unit Stop the operation The operation switch does NOT work well Turn OFF the power supply If the user interface display indicates the unit number the operatio...

Page 18: ...o insert the batteries on page 4 Make sure that the transmitter is NOT exposed to direct sunlight Check if there are any electronic starter type fluorescent lamps in the room Contact your dealer The u...

Page 19: ...utdoor unit Indoor outdoor unit combination fault Indoor unit Error code Description Indoor unit PCB abnormality Freeze up protection or high pressure control Fan motor DC motor abnormality Streamer u...

Page 20: ...channel MUST be between 1 11 Check if communication is OK See To confirm the wireless adapter connection status on page 12 Try to resetting to the factory default and repeat the setting See To reset t...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...3P485919 7C 2017 12 Copyright 2017 Daikin...

Reviews: