background image

4 Operation

Operation manual

9

(C)(F)TXA15~50A2V1B(W)(S)(T)
Daikin room air conditioner
3P485919-7C – 2017.12

2

To  stop  operation,  press 

  until  both  symbols  disappear

from the LCD.

4.3.5

Powerful operation

This  operation  quickly  maximizes  the  cooling/heating  effect  in  any
operation mode. You can get the maximum capacity.

INFORMATION

Powerful operation CANNOT be used together with Econo,
Comfort  airflow,  Intelligent  eye  and  Outdoor  unit  quiet
operation. The last selected function takes priority.

Powerful  operation  will  NOT  increase  the  capacity  of  the
unit if it already operates at maximum capacity.

To start/stop Powerful operation

1

Press 

 to start.

Result: 

  is  displayed  on  the  LCD.  Powerful  operation  runs

for 20 minutes; after that, operation returns to the previously set
mode.

Mode

Airflow rate

Cooling/Heating/Automatic

▪ To  maximize  the  cooling/

heating  effect,  the  capacity  of
outdoor unit is increased.

▪ The  airflow  rate  is  fixed  to  the

maximum setting.

Drying

▪ The  temperature  setting  is

lowered by 2.5°C.

▪ The  airflow  rate  is  slightly

increased.

Fan only

The airflow rate is fixed to the
maximum setting.

2

Press 

 to stop.

Result: 

 disappears from the LCD.

Note:

  Powerful  operation  can  only  be  set  when  the  unit  is  running.

Press 

 to cancel this mode; 

 disappears from the LCD.

4.3.6

Econo and Outdoor unit quiet operation

Econo operation

This  is  a  function  which  enables  efficient  operation  by  limiting  the
maximum power consumption value. This function is useful for cases
in which attention should be paid to ensure a circuit breaker will not
trip when the product runs alongside other appliances.

INFORMATION

▪ Powerful and Econo operation CANNOT be used at the

same time. The last selected function takes priority.

▪ Econo  operation  reduces  power  consumption  of  the

outdoor  unit  by  limiting  the  rotation  speed  of  the
compressor.  If  power  consumption  is  already  low,
Econo  operation  will  NOT  further  reduce  power
consumption.

Outdoor unit quiet operation

Use  Outdoor  unit  quiet  operation  when  you  want  to  decrease  the
noise level of the outdoor unit. 

Example: 

 At night.

INFORMATION

▪ Powerful and Outdoor unit quiet operation CANNOT be

used at the same time. The last selected function takes
priority.

▪ This  function  is  only  available  in  Automatic,  Cooling,

and Heating operation.

▪ Outdoor unit quiet operation limits the rotation speed of

the compressor. If the rotation speed of compressor is
already  low,  Outdoor  unit  quit  operation  will  NOT
further reduce the compressor rotation speed.

To start/stop Econo and Outdoor unit quiet
operation

1

Press 

 one or more times.

Result: 

The setting will change as follows.

Display

Operation

Econo

Outdoor unit quiet

+

Econo and Outdoor unit quiet

Both deactivated

2

To  stop  operation,  press 

  until  both  symbols  disappear

from the LCD.

Note: 

  Econo  operation  can  be  only  set  when  the  unit  is  running.

Pressing 

 cancels the setting and 

 disappears from the LCD.

Note: 

 

  remains  on  the  LCD,  even  if  you  turn  off  the  unit  using

the user interface or indoor unit ON/OFF switch.

4.4

Flash streamer air cleaning
operation

Streamer  generates  a  high-speed  electron  stream  with  a  high
oxidizing power, reducing bad odours and viruses. Together with the
titanium  apatite  deodorizing  filter  and  the  air  filters,  this  function
cleans the air in the room.

INFORMATION

▪ The  high-speed  electrons  are  generated  and  go  away

inside the unit to ensure safe operation.

▪ The streamer discharge may generate a fizzing sound.

▪ If  the  airflow  becomes  weak,  the  Streamer  discharge

may stop temporarily to prevent ozone smell.

4.4.1

To start/stop Flash Streamer operation

1

Press 

.

Result: 

 is displayed on the LCD and the air in the room is

cleaned.

2

To stop operation, press 

.

Result: 

 disappears from the LCD and operation stops.

4.5

OFF/ON timer operation

Timer  functions  are  useful  for  automatically  switching  the  air
conditioner on/off at night or in the morning. You can also use OFF
timer and ON timer in combination.

Summary of Contents for CTXA15A2V1BW

Page 1: ...ual Daikin room air conditioner CTXA15A2V1BW FTXA20A2V1BW FTXA25A2V1BW FTXA35A2V1BW FTXA42A2V1BW FTXA50A2V1BW CTXA15A2V1BS FTXA20A2V1BS FTXA25A2V1BS FTXA35A2V1BS FTXA42A2V1BS FTXA50A2V1BS CTXA15A2V1BT...

Page 2: ...Ag ion filter 16 6 8 To replace the titanium apatite deodorizing filter and the silver particle filter Ag ion filter 16 6 9 To close the front panel 16 6 10 To remove the front panel 16 6 11 To take f...

Page 3: ...rticle filter is interchangeable ON OFF button If the user interface is missing you can use the ON OFF button on the indoor unit to start stop operation When operation is started using this button the...

Page 4: ...Weekly timer is active Day of the week Icon Description Current time 2 2 3 To operate the user interface a 500 mm a Signal receiver Note Make sure that there are no obstacles within 500 mm under the s...

Page 5: ...rightness of the indoor unit display Adjust the brightness of the indoor unit display as desired or turn OFF the display 3 4 1 To set the brightness of the indoor unit display 1 Press for at least 2 s...

Page 6: ...Streamer To remove airborne allergens such as mold pollen adjuvant substances viruses bacteria Econo To use the system when you are also using other power consuming appliances To save energy Outdoor...

Page 7: ...adjust the airflow rate 1 Press to change the airflow setting as follows 4 3 3 Airflow direction When Adjust the airflow direction as desired What The system directs the airflow differently depending...

Page 8: ...elected Comfort airflow operation will be cancelled To turn ON OFF Vertical airflow function 1 Press for at least 2 seconds Result The menu appears on the display 2 Press or to change the menu screen...

Page 9: ...ady low Econo operation will NOT further reduce power consumption Outdoor unit quiet operation Use Outdoor unit quiet operation when you want to decrease the noise level of the outdoor unit Example At...

Page 10: ...t time are displayed on the LCD The timer lamp lights up INFORMATION Each time or is pressed the time setting advances by 10 minutes Holding the button down will change the setting rapidly 4 To stop o...

Page 11: ...ture Note The set temperature is only displayed when the mode setting is on 9 Press Result Temperature and time are set in ON timer Time is set in OFF timer Timer lamp lights orange Result New reserva...

Page 12: ...Smartphone tablet or another smart device with one of the following operating systems Android 4 0 3 or later iOS 7 1 2 or later Internet line and communication device such as a modem router etc Wirele...

Page 13: ...onds in the default screen Result The confirmation display menu appears 2 Keep pressing or until the AP setting display menu appears 3 Press to confirm the selection Result is blinking 4 Connect with...

Page 14: ...the air outlet of the unit Doing so may cause a reduced heating cooling effect or stop operation Turn off the main power supply switch to the unit when the unit is NOT used for longer periods of time...

Page 15: ...C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brush Possible consequence The surface finishing peels off DANGER RISK OF ELECTROCU...

Page 16: ...or 10 to 15 minutes in warm water Do NOT remove the filter from frame 3 After washing shake off remaining water and dry the filter in the shade Do NOT wring out the filter when removing water 6 8 To r...

Page 17: ...main power switch If water leaks from the unit Stop the operation The operation switch does NOT work well Turn OFF the power supply If the user interface display indicates the unit number the operatio...

Page 18: ...o insert the batteries on page 4 Make sure that the transmitter is NOT exposed to direct sunlight Check if there are any electronic starter type fluorescent lamps in the room Contact your dealer The u...

Page 19: ...utdoor unit Indoor outdoor unit combination fault Indoor unit Error code Description Indoor unit PCB abnormality Freeze up protection or high pressure control Fan motor DC motor abnormality Streamer u...

Page 20: ...channel MUST be between 1 11 Check if communication is OK See To confirm the wireless adapter connection status on page 12 Try to resetting to the factory default and repeat the setting See To reset t...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...3P485919 7C 2017 12 Copyright 2017 Daikin...

Reviews: