5 Energy saving and optimum operation

Operation manual

14

(C)(F)TXA15~50A2V1B(W)(S)(T)

Daikin room air conditioner

3P485919-7C – 2017.12

Result: 

The confirmation display (menu  ) appears.

2

Keep pressing 

 or 

 until the OFF menu appears.

3

Hold 

 for at least 2 seconds to confirm the selection.

Result: 

  is  blinking.  Communication  is  OFF.  The

operation and timer LEDs are blinking.

4

Press 

 to exit the menu.

Result: 

The display will return to the default screen.

5

Energy saving and optimum
operation

INFORMATION

▪ Even if the unit is turned OFF, it consumes electricity.

▪ When the power turns back on after a power break, the

previously selected mode will be resumed.

CAUTION

NEVER  expose  little  children,  plants  or  animals  directly  to
the airflow.

WARNING

Do NOT place objects below the indoor and/or outdoor unit
that  may  get  wet.  Otherwise  condensation  on  the  unit  or
refrigerant pipes, air filter dirt or drain blockage may cause
dripping,  and  objects  under  the  unit  may  get  dirty  or
damaged.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

CAUTION

Do  NOT  operate  the  system  when  using  a  room
fumigation-type  insecticide.  Chemicals  could  collect  in  the
unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air
conditioner and do NOT use sprays. Doing so may result in
a fire.

Observe  the  following  precautions  to  ensure  the  system  operates
properly.

▪ Prevent  direct  sunlight  from  entering  a  room  during  cooling

operation by using curtains or blinds.

▪ Ventilate  often.  Extended  use  requires  special  attention  to

ventilation.

▪ Keep doors and windows closed. If the doors and windows remain

open,  air  will  flow  out  of  your  room  causing  a  decrease  in  the
cooling or heating effect.

▪ Be  careful  NOT  to  cool  or  heat  too  much.  To  save  energy,  keep

the temperature setting at a moderate level.

▪ NEVER place objects near the air inlet or the air outlet of the unit.

Doing  so  may  cause  a  reduced  heating/cooling  effect  or  stop
operation.

▪ Turn off the main power supply switch to the unit when the unit is

NOT  used  for  longer  periods  of  time.  If  the  main  power  supply
switch  is  on,  the  unit  consumes  electricity.  Before  restarting  the
unit,  turn  on  the  main  power  supply  switch  6  hours  before
operation to ensure smooth running.

▪ Condensation  may  form  if  the  humidity  is  above  80%  or  if  the

drain outlet gets blocked.

▪ Adjust  the  room  temperature  properly  for  a  comfortable

environment.  Avoid  excessive  heating  or  cooling.  Notice  that  it
may  take  some  time  for  the  room  temperature  to  reach  the  set
temperature. Consider using the timer setting options.

▪ Adjust the air flow direction to avoid cool air from gathering on the

floor  or  warm  air  against  the  ceiling.  (Up  during  cooling  or  dry
operation to the ceiling and down during heating operation.)

▪ Avoid direct air flow to room inhabitants.

▪ Operate  the  system  within  the  recommended  temperature  range

(26~28°C for cooling and 20~24°C for heating) to save energy.

6

Maintenance and service

6.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance.

About the refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

In  Europe,  the 

greenhouse  gas  emissions

  of  the  total

refrigerant charge in the system (expressed as tonnes CO

2

equivalent) is used to determine the maintenance intervals.
Follow the applicable legislation.

Formula  to  calculate  the  greenhouse  gas  emissions:

GWP value of the refrigerant × Total refrigerant charge [in
kg] / 1000

Please contact your installer for more information.

WARNING

The  refrigerant  inside  the  unit  is  mildly  flammable,  but
normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater, or a cooker, this may result in fire, or the formation
of a harmful gas.

Turn  off  any  combustible  heating  devices,  ventilate  the
room,  and  contact  the  dealer  where  you  purchased  the
unit.

Do  NOT  use  the  unit  until  a  service  person  confirms  that
the  part  from  which  the  refrigerant  leaked  has  been
repaired.

Summary of Contents for CTXA15A2V1BW

Page 1: ...ual Daikin room air conditioner CTXA15A2V1BW FTXA20A2V1BW FTXA25A2V1BW FTXA35A2V1BW FTXA42A2V1BW FTXA50A2V1BW CTXA15A2V1BS FTXA20A2V1BS FTXA25A2V1BS FTXA35A2V1BS FTXA42A2V1BS FTXA50A2V1BS CTXA15A2V1BT...

Page 2: ...Ag ion filter 16 6 8 To replace the titanium apatite deodorizing filter and the silver particle filter Ag ion filter 16 6 9 To close the front panel 16 6 10 To remove the front panel 16 6 11 To take f...

Page 3: ...rticle filter is interchangeable ON OFF button If the user interface is missing you can use the ON OFF button on the indoor unit to start stop operation When operation is started using this button the...

Page 4: ...Weekly timer is active Day of the week Icon Description Current time 2 2 3 To operate the user interface a 500 mm a Signal receiver Note Make sure that there are no obstacles within 500 mm under the s...

Page 5: ...rightness of the indoor unit display Adjust the brightness of the indoor unit display as desired or turn OFF the display 3 4 1 To set the brightness of the indoor unit display 1 Press for at least 2 s...

Page 6: ...Streamer To remove airborne allergens such as mold pollen adjuvant substances viruses bacteria Econo To use the system when you are also using other power consuming appliances To save energy Outdoor...

Page 7: ...adjust the airflow rate 1 Press to change the airflow setting as follows 4 3 3 Airflow direction When Adjust the airflow direction as desired What The system directs the airflow differently depending...

Page 8: ...elected Comfort airflow operation will be cancelled To turn ON OFF Vertical airflow function 1 Press for at least 2 seconds Result The menu appears on the display 2 Press or to change the menu screen...

Page 9: ...ady low Econo operation will NOT further reduce power consumption Outdoor unit quiet operation Use Outdoor unit quiet operation when you want to decrease the noise level of the outdoor unit Example At...

Page 10: ...t time are displayed on the LCD The timer lamp lights up INFORMATION Each time or is pressed the time setting advances by 10 minutes Holding the button down will change the setting rapidly 4 To stop o...

Page 11: ...ture Note The set temperature is only displayed when the mode setting is on 9 Press Result Temperature and time are set in ON timer Time is set in OFF timer Timer lamp lights orange Result New reserva...

Page 12: ...Smartphone tablet or another smart device with one of the following operating systems Android 4 0 3 or later iOS 7 1 2 or later Internet line and communication device such as a modem router etc Wirele...

Page 13: ...onds in the default screen Result The confirmation display menu appears 2 Keep pressing or until the AP setting display menu appears 3 Press to confirm the selection Result is blinking 4 Connect with...

Page 14: ...the air outlet of the unit Doing so may cause a reduced heating cooling effect or stop operation Turn off the main power supply switch to the unit when the unit is NOT used for longer periods of time...

Page 15: ...C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brush Possible consequence The surface finishing peels off DANGER RISK OF ELECTROCU...

Page 16: ...or 10 to 15 minutes in warm water Do NOT remove the filter from frame 3 After washing shake off remaining water and dry the filter in the shade Do NOT wring out the filter when removing water 6 8 To r...

Page 17: ...main power switch If water leaks from the unit Stop the operation The operation switch does NOT work well Turn OFF the power supply If the user interface display indicates the unit number the operatio...

Page 18: ...o insert the batteries on page 4 Make sure that the transmitter is NOT exposed to direct sunlight Check if there are any electronic starter type fluorescent lamps in the room Contact your dealer The u...

Page 19: ...utdoor unit Indoor outdoor unit combination fault Indoor unit Error code Description Indoor unit PCB abnormality Freeze up protection or high pressure control Fan motor DC motor abnormality Streamer u...

Page 20: ...channel MUST be between 1 11 Check if communication is OK See To confirm the wireless adapter connection status on page 12 Try to resetting to the factory default and repeat the setting See To reset t...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...3P485919 7C 2017 12 Copyright 2017 Daikin...

Reviews: