15
|
Technical data
Installer reference guide
235
EHYH EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
EHYKOMB33AA*
Drain/fill valve
No (optional in connection set)
Shut‑off valves
No (optional in connection set)
Air purge valve
Yes (manual)
Domestic hot water circuit (not applicable for Switzerland)
Domestic hot water piping connections
Ø15 mm
Piping material
Cu
Gas/flue gas
Gas connection
Ø15 mm
Flue gas/combustion air connection
Concentric connection
Ø60/100 mm
Electrical
Power supply voltage
230 V
Power supply phase
1~
Power supply frequency
50 Hz
IP class
IPX4D
Absorbed power: full load
80 W
Absorbed power: standby
2 W
Auxiliary electricity consumption at full load
(elmax)
0.040 kW
Auxiliary electricity consumption at part load
(elmin)
0.015 kW
Auxiliary electricity consumption in standby
mode (P
SB
)
0.002 kW
Radio module
Power supply
230 V AC mains powered
Frequency range
868.3 MHz
Effective Radiated Power (ERP)
12.1 dBm
(a)
Index 'x' only valid for DE.
15.7.2 Energy-related products specifications
Technical product fiche in accordance to CELEX-32013R0811
Supplier
Daikin Europe N.V.,
Zandvoordestraat 300,
BE-8400 Oostende, Belgium
Type designation
EHYKOMB33AA*
Seasonal space heating energy efficiency class
—
—
A
Heat rated output
Prated
kW
27
Annual energy consumption
Q
HE
GJ
53
Seasonal space heating energy efficiency
η
S
%
93
Summary of Contents for Altherma EVLQ05+08CA
Page 249: ......
Page 250: ......
Page 251: ......
Page 252: ...4P355634 1F 2020 10 Copyright 2013 Daikin Verantwortung f r Energie und Umwelt...