8
|
Configuration
Installer reference guide
172
EHYH EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
Parameters on the gas boiler
Parameter
Setting
Range
Default
settings
Description
Service code
—
—
To access the installer settings,
enter the service code (=15)
Installation type
0~3
0
▪
0=Combi
▪
1=Heating only + external
domestic hot water tank
▪
2=Domestic hot water only
(no heating system required)
▪
3=Heating only
It is recommended not to
modify this setting.
Space heating pump
continuous
0~3
0
▪
0=Post purge period only
▪
1=Pump continuously active
▪
2=Pump continuously active
with MIT switch
▪
3=Pump on with external
switch
This setting has no effect.
Maximum space heating
power set
~85%
70%
Maximum power in heating.
This is a percentage of the
maximum set in parameter .
We strongly recommend not
modifying this setting.
.
Maximum capacity space
heating pump
—
80
There is no space heating
pump in the gas boiler.
Changing this setting has no
effect.
Maximum domestic hot water
power set
(not applicable for
Switzerland)
~100%
100%
Maximum power in instant
domestic hot water. This is a
percentage of the maximum
set in parameter . Because of
the 2-digit display, the highest
displayable value is 99. It is
however possible to set this
parameter to 100% (default
setting). We strongly
recommend not modifying this
setting.
Minimum supply temperature
of the heat curve
10°C~25°C
15°C
Do NOT modify this setting on
the boiler. Use the user
interface instead.
.
Maximum supply temperature
of the heat curve
30°C~90°C
90°C
Do NOT modify this setting on
the boiler. Use the user
interface instead.