10
|
Configuration
Installer reference guide
148
08CA + EHY EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
#
Code
Description
[A.3.1.2.1]
N/A
<< continuation
▪
Fixed/scheduled
: The desired leaving
water temperature is:
-
NOT weather-dependent (i.e., does NOT
depend
on
the
outdoor
ambient
temperature)
-
according a schedule. The scheduled
actions are On or OFF.
Remark:
This value can only be set in
leaving water temperature control.
▪
WD/scheduled
: The desired leaving water
temperature is:
-
weather-dependent (i.e., does depend on
the outdoor ambient temperature)
-
according a schedule. The scheduled
actions are On or OFF.
Remark:
This value can only be set in
leaving water temperature control.
#
Code
Description
[7.7.2.1]
[0‑00]
[0‑01]
[0‑02]
[0‑03]
Set weather-dependent heating
:
[0-00]
[0-01]
Ta
Tt
[0-03]
[0-02]
▪
T
t
: Target leaving water temperature
(additional)
▪
T
a
: Outdoor temperature
continued >>