10
|
Configuration
Installer reference guide
139
08CA + EHY EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
Quick wizard: Options
Domestic hot water settings
Following settings must be made accordingly.
#
Code
Description
[A.2.2.1]
[E‑05]
Domestic hot water preparation:
▪
0 (
No
): NOT possible
▪
1 (
Yes
)(default): Possible
[A.2.2.2]
[E‑06]
Domestic hot water tank installed in the system?
▪
0 (
No
)(default): the domestic hot water will be
produced by the boiler when there is a
demand.
▪
1 (
Yes
): the domestic hot water will be
produced by the tank.
Note:
For Switzerland, setting MUST be "1".
[A.2.2.3]
[E‑07]
What kind of domestic hot water tank is
installed?
▪
4 (
Type 5
). EKHWP.
▪
6 (
Type 7
) Third-party tank.
Range: 0~6.