5/6
Breadcrumb Field code
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
Setting name
A.8
[5-03]
0
A.8
[5-04]
10
A.8
[5-05]
50 A
A.8
[5-06]
50 A
A.8
[5-07]
50 A
A.8
[5-08]
50 A
A.8
[5-09]
20 kW
A.8
[5-0A]
20 kW
A.8
[5-0B]
20 kW
A.8
[5-0C]
20 kW
A.8
[5-0D]
0
A.8
[5-0E]
0
A.8
[6-00]
R/W
2~20°C, step: 1°C
2°C
A.8
[6-01]
R/W
0~10°C, step: 1°C
2°C
A.8
[6-02]
0
A.8
[6-03]
0
A.8
[6-04]
0
A.8
[6-05]
0
A.8
[6-06]
0
A.8
[6-08]
R/W
2~20°C, step: 1°C
5°C
A.8
[6-09]
0
A.8
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
60°C
A.8
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
50°C
A.8
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
50°C
A.8
[6-0D]
R/W
0: Reheat only
1: sched.
2: Scheduled only
A.8
[6-0E]
R/W
[E-06]=1
[E-07] = 0: 40~70°C, step: 1°C, 70°C
[E-07] = 4: 40~75°C, step: 1°C, 75°C
[E-07] = 6: 40~60°C, step: 1°C, 60°C
[E-06]=0
40~65°C, step: 1°C,
65°C
A.8
[7-00]
0
A.8
[7-01]
2
A.8
[7-02]
0
A.8
[7-03]
R/W
0~6, step: 0,1
2,5
A.8
[7-04]
R/W
0: Economical
1: Ecological
A.8
[7-05]
0
A.8
[8-00]
R/W
0~20 min, step 1 min
1 min
A.8
[8-01]
R/W
5~95 min, step: 5 min
30 min
A.8
[8-02]
R/W
0~10 hour, step: 0,5 hour
0,5 hour
A.8
[8-03]
50
A.8
[8-04]
95
A.8
[8-05]
R/W
0: No
1: Yes
A.8
[8-06]
R/W
0~10°C, step: 1°C
5°C
A.8
[8-07]
18°C
A.8
[8-08]
20°C
A.8
[8-09]
R/W
[9-01]~[9-00]°C, step: 1°C
45°C
A.8
[8-0A]
R/W
[9-01]~[9-00]°C, step: 1°C
40°C
A.8
[8-0B]
13
A.8
[8-0C]
10
A.8
[8-0D]
16
A.8
[8-0E]
R/W
-15~25°C, step: 1°C
-
5°C
A.8
[9-00]
R/W
37~80°C, step: 1°C
55°C
A.8
[9-01]
R/W
15~37°C, step: 1°C
25°C
A.8
[9-02]
22°C
A.8
[9-03]
5°C
A.8
[9-04]
1
A.8
[9-05]
25°C
A.8
[9-06]
55°C
A.8
[9-07]
5°C
A.8
[9-08]
22°C
A.8
[9-0C]
R/W
1~6°C, step: 0,5°C
1 °C
A.8
[9-0D]
R/W
0~8,step:1
6
A.8
[9-0E]
0~8,step:1
6
A.8
[A-00]
0
A.8
[A-01]
0
A.8
[A-02]
0
A.8
[A-03]
0
A.8
[A-04]
0
A.8
[B-00]
0
A.8
[B-01]
0
A.8
[B-02]
0
A.8
[B-03]
0
A.8
[B-04]
0
A.8
[C-00]
R/W
0: Solar priority
1: Heat pump priority
A.8
[C-01]
0
A.8
[C-02]
R/W
0: Boiler
1: Bivalent boiler
A.8
[C-03]
R/W
-25~25°C, step: 1°C
0°C
What is the boiler system type?
Bivalent activation temperature.
--
--
--
--
Domestic heating water priority.
--
--
--
--
--
--
--
Room temperature hysteresis.
Pump speed limitation
--
--
--
--
--
--
--
--
--
What is the ambient temp for boiler only operation?
What is the maximum desired LWT for main zone in heating?
What is the mimimum desired LWT for main zone in heating?
--
Leaving water temperature maximum modulation.
--
--
What is the desired comfort main LWT in heating?
What is the desired eco main LWT in heating?
--
Minimum running time for domestic hot water operation.
Maximum running time for domestic hot water operation.
Anti-recycling time.
--
--
Allow modulation of the LWT to control the room temp?
--
--
--
PE factor
Savings mode
--
--
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
What is the desired reheat temperature?
What is the desired DHW production type?
What is the maximum temperature setpoint?
--
--
--
--
What is the hysteresis to be used in reheat mode?
--
--
--
The temperature difference determining the heat pump ON temperature.
The temperature difference determining the heat pump OFF temperature.
--
--
--
--
--
--
--
--
--
--
4P564438-1 - 2018.12