3/6
Breadcrumb Field code
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
Setting name
A.3.1.1.1
R/W
0: Fixed
1: Weather dep.
2: Fixed / scheduled
3: WD / scheduled
A.3.1.1.2.1
[9-01]
Temperature range
Minimum temp (heating)
R/W
15~37°C, step: 1°C
25°C
A.3.1.1.2.2
[9-00]
Temperature range
Maximum temp (heating)
R/W
37~80°C, step: 1°C
55°C
A.3.1.1.5
[8-05]
R/W
0: No
1: Yes
A.3.1.1.7
[2-0C]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
└────────────────── Delta T source
A.3.1.3
[1-0B]
Heating
R/W
3~66°C, step: 1°C
10°C
└─ Room thermostat
A.3.2.1.1
[3-07]
Room temp. range
Minimum temp (heating)
R/W
12~18°C, step: A.3.2.4
12°C
A.3.2.1.2
[3-06]
Room temp. range
Maximum temp (heating)
R/W
18~30°C, step: A.3.2.4
30°C
A.3.2.2
[2-0A]
R/W
-5~5°C, step: 0,5°C
0°C
A.3.2.4
R/W
0: 1°C
1: 0,5°C
└─ Operation range
A.3.3.1
[4-02]
R/W
14~35°C, step: 1°C
35°C
└─ Domestic hot water (DHW)
└─ Type
A.4.1
[6-0D]
R/W
0: Reheat only
1: sched.
2: Scheduled only
└─ Disinfection
A.4.4.1
[2-01]
R/W
0: No
1: Yes
A.4.4.2
[2-00]
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
A.4.4.3
[2-02]
R/W
0~23 hour, step: 1 hour
23
A.4.4.4
[2-03]
R/W
fixed value
60°C
A.4.4.5
[2-04]
R/W
40~60 min, step: 5 min
40 min
└─ Maximum setpoint
A.4.5
[6-0E]
R/W
[E-06]=1
[E-07] ≠ 6: 40~75°C, step: 1°C,
75°C
[E-07] = 6: 40~60°C, step: 1°C,
60°C
[E-06]=0
40~65°C, step: 1°C,
65°C
└─ SP mode
A.4.6
R/W
0: Fixed
1: Weather dep.
└─ Weather dependent curve
A.4.7
[0-0B]
Weather-dependent curve
DHW setpoint for high ambient temp. for DHW
WD curve.
R/W
35~[6-0E]°C, step: 1°C
55°C
A.4.7
[0-0C]
Weather-dependent curve
DHW setpoint for low ambient temp. for DHW
WD curve.
R/W
45~[6-0E]°C, step: 1°C
60°C
A.4.7
[0-0D]
Weather-dependent curve
High ambient temp. for DHW WD curve.
R/W
10~25°C, step: 1°C
15°C
A.4.7
[0-0E]
Weather-dependent curve
Low ambient temp. for DHW WD curve.
R/W
-40~5°C, step: 1°C
-10°C
└─ Heat sources
└─ Boiler
A.5.2.2
[5-01]
R/W
-15~35°C, step: 1°C
5°C
A.5.2.3
[8-0E]
R/W
-15~25°C, step: 1°C
-
5°C
└─ System operation
└─ Auto restart
A.6.1
[3-00]
R/W
0: No
1: Yes
└─ Pwr consumpt. Control
A.6.3.1
[4-08]
R/W
0: No limitation
1: Continuous
2: Digital inputs
A.6.3.2
[4-09]
R/W
0: Current
1: Power
A.6.3.3
[5-05]
R/W
0~50 A, step: 1 A
50 A
A.6.3.4
[5-09]
R/W
0~20 kW, step: 0,5 kW
20 kW
└─ Averaging time
A.6.4
[1-0A]
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
└─ Ext amb. sensor offset
A.6.5
[2-0B]
R/W
-5~5°C, step: 0,5°C
0°C
└─ Savings mode
A.6.7
[7-04]
R/W
0: Economical
1: Ecological
└─ Emergency
A.6.C
R/W
0: Manual
1: Automatic
└─ Disable protective Function
kW value
Duration
Equilibrium temp.
Boiler only ambient temp.
Mode
Start time
Temperature target
Emitter type
Room temp. offset
Room temp. step
Space heating OFF temp
Operation day
Type
Amp. value
LWT setpoint mode
Modulated LWT
Disinfection