![background image](http://html.mh-extra.com/html/daikin/altherma-ehy2komb28aa/altherma-ehy2komb28aa_installers-reference-manual_501275084.webp)
14 Maintenance and service
Installer reference guide
84
EJHA EHY32AA
Daikin Altherma Hybrid hydrosplit heat pump
4P531180-1 – 2018.06
3
Close the gas tap.
4
Remove the front panel.
5
Wait until the appliance has cooled down.
6
Unscrew the coupling nut at the base of the flue pipe by turning
counterclockwise.
7
Slide the flue pipe upwards by turning it clockwise until the
bottom of the pipe is above the condensate drain pan
connection.
8
Pull the bottom of the pipe forwards and remove the pipe
downwards by turning the pipe alternately clockwise and
counterclockwise.
9
Lift the condensate drain pan on the left-hand side from the
connection to the condensate trap.
10
Turn it to the right with the condensate trap connection over the
edge of the base tray.