![background image](http://html.mh-extra.com/html/daikin/4mxs115hv2c/4mxs115hv2c_service-manual_501134022.webp)
Removal of PCBs
Si12-996
20
Removal Procedure
8
Open the terminal
board.
9
Disconnect the 4
connectors.
A3: Red
B3: Yellow
C3: Blue
D3: Orange
10
Release the 2 wire
harnesses from the
terminal board.
11
Disconnect the relay
connector for the
reactor.
Remove the screw and
remove the plastic
band.
Step
Procedure
Points
(R11104)
Terminal board
(R11105)
C3
A3
D3
B3
(R11106)
Plastic band
Reactor
(R11107)