![background image](http://html.mh-extra.com/html/daikin/4mxs115hv2c/4mxs115hv2c_service-manual_501134032.webp)
Removal of Compressor
Si12-996
30
Removal Procedure
7. Removal of Compressor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove the terminal
cover.
2
Pull out the 3 lead wires
with pliers.
U:red, V:yellow, W:blue
3
Remove the overload
protector (OL).
Terminal
cover
(R11171)
(R9471)
W(blue)
U(red)
V(yellow)
OL