![background image](http://html.mh-extra.com/html/daikin/4mxs115hv2c/4mxs115hv2c_service-manual_501134016.webp)
Removal of Electrical Box
Si12-996
14
Removal Procedure
3. Removal of Electrical Box
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove the screw from
the stop valve mounting
plate.
2
Remove the 2 screws
to detach the earth
wires.
3
Remove the screw on
the partition plate.
(R11079)
Stop valve mounting plate
(R11081)
Earth wires
(R11080)
Partition plate