9-5
Chapter 9
T
roubleshooting
T
ROUBLESHOOTING
T
ROUBLESHOOTING
C
HAPTER
9
13
There are blowholes.
There is a problem in the
shielding gas.
Check that there is no abnormality in the gas
cylinder or gas hose.
The chip of the welding torch
wore out.
Replace the chip.
14
Continuous output of the WCR
signal is shown on the monitor
of the robot.
(The WCR signal is used for
communicating with the robot to
check the presence of the
welding current.)
The WCR relay of welding power
source is broken.
The WCR relay on the printed circuit board PCB1
(P30099P00) needs to be replaced.
Contact your dealer.
15
The password is lost.
-
Contact your dealer.
No.
Problem
Possible cause
Corrective action
Summary of Contents for OTC Welbee Inverter W400
Page 2: ......
Page 8: ...vi MEMO...
Page 56: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 22...
Page 116: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Page 134: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Page 146: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Page 150: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram...
Page 151: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10...
Page 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 12...