S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6-48
6.7.2.49 F78
:
Prevention of unintended torch switch operation
Sets whether or not to output the error code when welding is not performed for a certain time after the
pre-flow to avoid an unexpected torch switch operation.
• [ON] : If welding is not performed for five seconds after the pre-flow, Error code "E-011" is displayed on
the left and right digital meters and the output of the welding power source stops.
• [OFF]: disables the function. (
-
6.7.2.50 F81: Setting to use torch switch in TIG mode
When "DC TIG" welding is selected for the welding method, ON/OFF of the output is controlled by the
torch switch.
• [ON]: This function is enabled. Crater sequence, gas control, welding management functions are also
enabled.
• [OFF]: This function is disabled.